Skip to main content
. 2024 Mar 19;25:221. doi: 10.1186/s12891-024-07351-y

Table 3.

Intra- and Inter-rater Reliabilities of SWE for Mean Shear Modulus of popliteus and medial and lateral gastrocnemius muscles

Reliability Muscle ICC (95%CI) SEM MDC CV (%)

Intra-rater

(Inter-day)

First Examiner PM 0.968 (0.932—0.985) 0.52 1.43 23.03
GM 0.922 (0.835—0.963) 0.84 2.29 20.08
GL 0.912 (0.815—0.958) 0.96 2.62 22.69
Second Examiner PM 0.986 (0.971—0.993) 0.36 0.99 26.29
GM 0.955 (0.905—0.979) 0.61 1.68 22.43
GL 0.942 (0.878—0.972) 0.79 2.16 24.70
Inter-rater Test PM 0.956 (0.908—0.979) 0.65 1.78 25.33
GM 0.905 (0.801—0.955) 0.91 2.49 22.16
GL 0.927 (0.848—0.969) 0.92 2.52 24.91
Retest PM 0.932 (0.858—0.968) 0.78 2.13 24.59
GM 0.766 (0.509—0.889) 1.43 3.94 22.59
GL 0.875 (0.737—0.940) 1.12 3.07 22.93

SWE Shear Wave Elastography, PM popliteus muscle, GM medial gastrocnemius, GL lateral gastrocnemius, ICC intraclass correlation coefficient, SEM standard error of measurement, MDC minimal detectable change, CV coefficient of variation