Table 2.

Sensitivity, specificity, and accuracy of nonattenuation correction, CT attenuation correction, and gated myocardial perfusion imaging in single-photon emission computed tomography studies for overall and right coronary artery disease

NAC CT-AC GMPI P value# P value&

Overall (n = 181)
 Sensitivity 75.7 52.7 51.4 0.002# 0.869
 Specificity 55.1 86.9 96.3 < 0.001# 0.014&
 Accuracy 63.5 72.9 77.9 0.003# 0.272
RCA (n = 181)
 Sensitivity 60.0 26.0 52.0 0.420  0.008&
 Specificity 64.9 93.1 94.7 < 0.001#  0.606
 Accuracy 63.5 74.6 82.9 < 0.001# 0.054

CAD, coronary artery disease; LAD, left anterior descending coronary artery; LCX, left circumflex coronary artery; RCA, right coronary artery.

CT-AC, CT attenuation correction; GMPI, gated myocardial perfusion imaging; NAC, nonattenuation correction; RCA, right coronary artery.

P value refers to test accuracy.

#

P<0.05 for NAC and GMPI.

&

P<0.05 for CT-AC and GMPI.