Published in final edited form as: Nucl Med Commun. 2019 May;40(5):491–498. doi: 10.1097/MNM.0000000000001009

Table 3.

Sensitivity, specificity, and accuracy of nonattenuation correction, CT attenuation correction, and gated myocardial perfusion imaging in single-photon emission computed tomography studies for men and overweight individuals

NAC CT-AC GMPI P value# P value&

Men (n = 123)
 Sensitivity 77.0 49.2 55.7 0.013# 0.468
 Specificity 35.5 87.1 95.2 < 0.001# 0.114
 Accuracy 56.1 68.3 75.6 0.001# 0.201
Overweight individuals (n = 117)
 Sensitivity 71.4 49.0 49.0 0.023# 1
 Specificity 48.5 88.2 97.1 < 0.001# 0.049&
 Accuracy 58.1 71.8 77.0 0.002# 0.369

CT-AC, CT attenuation correction; GMPI, gated myocardial perfusion imaging; NAC, nonattenuation correction.

P value refers to test accuracy.

#

P<0.05 for NAC and GMPI.

&

P<0.05 for CT-AC and GMPI.