Rating conditions for commercial refrigeration products and performance requirements for practical eC cooling systems.

Category Tc [°C] Th [°C] Cooling (heating) power and corresponding ΔTspana ΔTspan,max at 0 load [K]b
Split-type air-conditioner (cooling)61 15.5c 35 2.5 kW at 29.5 K 59
Split-type air-conditioner (heat pump)62 −7 20 3.0 kW at 37 K 74
Domestic refrigerator (fresh food)63 4 32 100 W at 38 K 76
Dehumidifier64 23.7d 27 1 kW at 13.3 K 26.6

aAssuming 5 K heat transfer temperature difference on each side.

bAssuming a linear characteristic curve between temperature span and cooling. (heating) power, which implies that the maximum cooling (heating) power is twice the value listed in the table.

cDew point temperature corresponding to the standard dry bulb of 27 °C and wet bulb of 19 °C.

dDew point temperature corresponding to the standard dry bulb of 27 °C and wet bulb of 24 °C.