Skip to main content
. 2024 Mar 8;15:1341752. doi: 10.3389/fimmu.2024.1341752

Table 3.

Plasma biomarkers in sepsis phenotypes.

Sepsis Phenotype Hypoimmune Hyperimmune Hybrid Control P value
Number of Subjects N=14 N=23 N=8 N=8
Laboratory Values
WBC ×109/L 13 ± 6 16 ± 4 16 ± 8 NA NS
Neutrophils ×109/L 4 ± 2 8 ± 4 4 ± 2 NA P<0.01 Hyperimmune vs. Hypoimmune and Hybrid
Bands (%) 1 ± 2 3 ± 12 1 ± 2 NA NS
Plasma Markers of Endothelial Damage (Mean ± SEM)
vWF (pg/ml) 10753 ± 1340 8276 ± 1363 6699 ± 752 3221 ± 539 P<0.01 vs. control
ICAM-1 (ng/ml) 145 ± 30 178 ± 36 192 ± 52 42 ± 3 P<0.001 vs. control
Angiopoietin (pg/ml) 5441 ± 1054 6526 ± 1631 8563 ± 4755 474 ± 37 P<0.001 vs. control
Plasma Cytokine Biomarkers (Mean ± SEM)
IL-6 (pg/ml) 191 ± 96 184 ± 46 332 ± 107 2 ± 0.3 P<0.02 vs. control
IL-8 (pg/ml) 105 ± 49 207 ± 80 393 ± 311 2 ± 0.4 P<0.02 vs. control