Skip to main content
. 2024 Mar 22;24:374. doi: 10.1186/s12903-024-03986-4

Table 2.

Crown occlusion adjustment in test and control groups

Test Control p-value
Mean ± SD (95%CI) Mean ± SD (95%CI)
Maximum Occlusion Adjustment (µm) Mesial Crown 263.74 ± 132.57 (179.51, 347.97) 468.82 ± 208.54 (336.31, 601.32)
Distal Crown 295.59 ± 90.45 (238.12, 353.06) 490.36 ± 207.26 (358.67, 622.04)
Mean 279.67 ± 112.17 (232.30, 327.03) 479.59 ± 203.63 (393.60, 565.57) < 0.001
Area of Occlusion Adjustment (mm2) Mesial Crown 10.48 ± 9.13 (4.68, 16.28) 25.16 ± 15.37 (15.41, 34.92)
Distal Crown 13.76 ± 11.91 (6.19, 21.89) 25.08 ± 13.50 (16.50, 33.66)
Mean 12.12 ± 10.51 (7.68, 16.56) 25.12 ± 14.14 (19.15, 31.09) 0.013

SD: Standard deviation; 95% CI: 95% Confidence interval. A linear mixed model was conducted to evaluate fixed effect of groups and crown positions on maximum occlusion adjustment and area of occlusion adjustment of crowns