Skip to main content
. 2023 Dec 20;8(2):2300223. doi: 10.1002/gch2.202300223

Table 6.

Exergy destruction and exergy efficiency for each component.

Component Exergy destruction [kW] Exergy efficiency [%]
Heliostats 21 465.0 64.27
Receiver 16 113.0 58.28
Heat exchanger 1 1079.0 91.65
Main turbine 778.6 97.25
HTR 643.0 92.91
LTR 650.0 91.45
Heat exchanger 667.6 81.95
Main compressor 877.0 92.42
Pump 405.9 15.10
tCO2 turbine 424.9 82.69
Condenser 258.0 29.48
Pre‐compressor 301.0 86.68