Table 2.
MIPCa detection performance of WSUNet.
| PI-RADS | Training set | Testing set | ||
|---|---|---|---|---|
| AUC | Sensitivity∗ | AUC | Sensitivity∗ | |
| All (1-5) | 0.798 (0.775-0.819) | 0.817 [272/333] (0.781-0.850) |
0.764 (0.728-0.798) | 0.797 [94/118] (0.737-0.856) |
| ≥3 | 0.794 (0.773-0.815) | 0.814 [263/323] (0.780-0.848) |
0.762 (0.725-0.795) | 0.803 [94/117] (0.744-0.863) |
Note. Data in parentheses are 95% CIs. AUC = area under the receiver operating characteristic curve. ∗Data are percentages, with number of participants in brackets. PI-RADS refers to the maximum PI-RADS for all outlined lesions in one examination. Since most of the patient's PI-RAD is greater than 3, so this part of the data has been presented alone. MIPCa detection refers to the prediction of systematic biopsy.