Skip to main content
. 2024 Mar 26;14:7195. doi: 10.1038/s41598-024-57708-5

Table 2.

Multiple linear regression function for PCSK9.

Nonstandardized coefficients Typified coefficients t P value IC (95%) for B
B Typical error
iEAT 0.002 0.002 0.374 3.389 0.001 0.001 to 0.003
HbA1c 0.029 0.012 0.266 2.411 0.019 0.005 to 0.052
Constant 0.070 0.091 0.769 0.445 − 0.112 to 0.252

To evaluate the adjustment of the regression model to the observed data, different statistics were used, such as the multiple correlation coefficient (R = 0.498) and the coefficient of determination (R2 = 0.248). The R2 value indicates that 25% of the variation in PCSK9 is explained by the model. The corrected R2 is 0.225. The significance value of F (Fisher distribution) = 10.56 with a P value < 0.001 confirms that the model is appropriate.

Proconvertase subtilisin-kexin 9 (PCSK9); Epicardial adipose tissue index (iEAT).