Table 4. Radiologic Outcome of the Patients (Pauwels Classification Type III).

Variable FNS device (n = 12) Cannulated screw (n = 17) p-value
Garden alignment index (AP view) 0.246
Good 12 (100.0) 14 (82.4)
Poor 0 3 (17.6)
Garden alignment index (lateral view) 1.000
Good 12 (100.0) 16 (94.1)
Poor 0 1 (5.9)
Lowell’s criteria 0.428
Intact S 6 (50.0) 6 (35.3)
Broken S 6 (50.0) 11 (64.7)
CT reduction status 0.703
Displacement ≤ 2 mm 8 (66.7) 9 (52.9)
Displacement > 2 mm 4 (33.3) 8 (47.1)
Sliding distance (mm) 4.4 ± 3.3 6.0 ± 4.0 0.368
Outcome 0.449
Union 9 (75.0) 10 (58.8)
Failure 3 (25.0) 7 (41.2)
Time to union (mo) 4.8 ± 0.8 6.8 ± 1.5 0.042

Values are presented as number (%) or mean ± standard deviation.

FNS: Femoral Neck System (DePuy Synthes), AP: anteroposterior, CT: computed tomography.