Skip to main content
. 2024 Jan 10;37(1):60–71. doi: 10.1007/s10278-023-00930-w

Table 3.

The impact of different channel numbers and different loss functions on IVPSQA (MEAN + STD)

A: RTDose → PDose B: RTDose + CT → PDose
Metrics SSIM RMSE (%) MAE (%) SSIM RMSE (%) MAE (%)
2 channels 0.9982 ± 0.0007 0.3475 ± 0.1459 0.1276 ± 0.0718 0.9976 ± 0.0009 0.3568 ± 0.1464 0.1450 ± 0.0719
4 channels 0.9983 ± 0.0007 0.3409 ± 0.1420 0.1237 ± 0.0723 0.9980 ± 0.0007 0.3450 ± 0.1421 0.1379 ± 0.0733
6 channels 0.9983 ± 0.0007 0.3511 ± 0.1544 0.1282 ± 0.0790 0.9980 ± 0.0008 0.3516 ± 0.1528 0.1394 ± 0.0816
L1-norm 0.9982 ± 0.0007 0.3475 ± 0.1459 0.1276 ± 0.0718 0.9976 ± 0.0009 0.3568 ± 0.1464 0.1450 ± 0.0719
L2-norm 0.9982 ± 0.0008 0.3510 ± 0.1491 0.1301 ± 0.0789 0.9965 ± 0.0008 0.3610 ± 0.1422 0.1630 ± 0.0745