Table 4.
ROC analysis of VVR before weaning, mechanical ventilation duration before weaning, and mSOFA on weaning day for predicting weaning failure in post-cardiac surgery patients.
| Variables | AUC | P | Optimal cut-off value | 95% CI | Sensitivity | Specificity | |
|---|---|---|---|---|---|---|---|
| Lower limit | Upper limit | ||||||
| VVR before weaning (score) | 0.793 | <0.001 | 18.46 | 0.740 | 0.845 | 0.698 | 0.801 |
| Mechanical ventilation duration before weaning (h) | 0.738 | <0.001 | 20.50 | 0.662 | 0.782 | 0.709 | 0.758 |
| mSOFA on weaning day (score) | 0.722 | <0.001 | 4.33 | 0.662 | 0.782 | 0.547 | 0.774 |
AUC, area under the receiver operating characteristic curve; CI, confidence interval; VVR, vasoactive-ventilation-renal score; mSOFA, modified sequential organ failure assessment.