Skip to main content
. 2024 Mar 28;15:2726. doi: 10.1038/s41467-024-46756-0

Fig. 2. Fire-safety performance.

Fig. 2

a Bar graphs of LOI values for expandable graphite (EG), tris(1-chloro-2-propyl) phosphate (TCPP), and K-salts filled FPUF. b Comparison of LOI values from this study with the recent works5460. c Bar graph of LOI values for FPUF with varying additions of K-formate and K-malate. d Fire performance index (FPI) and fire growth index (FGI) of K-formate and K-malate filled FPUF. e Bar graphs of carbon dioxide yield (CO2Y) before and after ignition of K-formate and K-malate filled FPUF under cone calorimeter test. f Concentrations of CO2 obtained from cone calorimeter coupled with FTIR. g Concentrations of CO2, HCN and NOx in the smoke toxicity test. h General conventional index of toxicity (CITG) obtained from smoke toxicity tests. All error bars represent a particular confidence interval.