Skip to main content
. 2024 Feb 2;5(3):174–181. doi: 10.1016/j.hroo.2024.01.006

Table 3.

1-year AF recurrence composite outcome for patients with impedance drop above or below the best-predicting threshold

Patients Events Adjusted OR (95% CI)
Average impedance drop
>7.2 Ω 119 15 (12.6) Reference
≤7.2 Ω 123 42 (34.1) 3.51 (1.39–9.50)
Right WACA impedance drop
>7.2 Ω 104 12 (11.5) Reference
≤7.2 Ω 138 45 (32.6) 4.32 (1.57–13.2)
Left WACA impedance drop
>7.2 Ω 139 24 (17.3) Reference
≤7.2 Ω 103 33 (32.0) 2.97 (1.27–7.27)

The composite outcome includes AF hospitalization, repeat ablation, direct current cardioversion, or initialization of new antiarrhythmic drugs post–blanking period.

AF = atrial fibrillation; CI = confidence interval; OR = odds ratio; WACA = wide antral circumferential ablation.

A full list of ORs for all the variables in multivariable analysis can be found in Supplemental Tables 4–6.