Skip to main content
. Author manuscript; available in PMC: 2024 Apr 2.
Published in final edited form as: Addit Manuf. 2024 Mar;84:10.1016/j.addma.2024.104082. doi: 10.1016/j.addma.2024.104082

Table 1.

Working curve fit parameters and experimental conditions for participant-provided datasets.

λa (nm) Irradiance (mW cm−2) Dp (μm) Ec (mJ cm−2) Cd,minb (μm) Cd,maxc (μm) Dp,reportedd (μm) Ec,reportedd (mJ cm−2) Light Source Thickness Measurement Thickness Precision (μm)
Dataset 1 405 10.0 70 ± 2 20 ± 3 5 102 70 ± 2 20 ± 3 DLP printer Low force micrometer ± 0.1
Dataset 2 405 5.36 69 ± 4 10 ± 3 60 160 69 9.951 Top-down light exposure Digital thickness gauge ± 25
Dataset 3 405 1.987 167 ± 5 50 ± 9 68 329 168 50.486 DLP printer Micrometer ± 1
Dataset 4 405 Unknown 108 ± 3 26 ± 5 40 320 116.3 30.0 SLA printer Calipers Unknown
Dataset 5 405 12 134 ± 7 50 ± 20 32 184 127 ± 10 45 ± 6 Laser Not reported
Dataset 6 405 6.96 119 ± 8 40 ± 20 17.50 286.14 121 ± 4 40 ± 2 Filtered broadband UV lamp Rheometer Unknown
Dataset 7 405 21 71 ± 2 20 ± 2 46.94 109.51 70.825 20.284 DLP printer LSCMh ± < 0.05
Dataset 8 405 9.231 169 ± 5 40 ± 7 24.13 560.07 132 33.476 DLP printer Micrometer Unknown
Dataset 9 405 10.0 93 ± 3 19 ± 3 18 309 95.3 20.2 DLP printer Dial micrometer ± 1
Dataset 10 405 3.031 112 ± 4 27 ± 5 64 250 113.85 26.811 LCD printer Micrometer Unknown
Dataset 11 405 10.33 109 ± 9 16 ± 6 57.5 162.5 109 ± 9 16 ± 2 DLP printer Digital caliper Unknown
Dataset 12 405 8.22 119 ± 8 18 ± 6 50.0 145.0 119 ± 8 18 ± 1 DLP printer Digital caliper Unknown
Dataset 13 405 6.15 90 ± 10 14 ± 7 57.5 110.0 92 ± 10 14 ± 2 DLP printer Digital caliper Unknown
Dataset 14 405 402–1660 190 ± 20 700 ± 500 50 575 173.7
201.5
625.9
698.9
Top-down LED spot curing system Calipers Unknown
Dataset 15 405 2.7 89 ± 6 18 ± 6 0 244 89 18.376 LCD printer Dial micrometer ± 1
Dataset 16 405 63.9 156 ± 7 9 ± 2 346.8 736.7 155.77 8.54 Top-down Independent LED Stylus profilometer ± < 0.05
Dataset 17 405 32.34 136 ± 6 17 ± 5 81.3 436.5 136.34 17.45 Top-down Independent LED Stylus profilometer ± < 0.05
Average 405 e 120 ± 40 60 ± 160 58 295
Aggregate 405 f 89 ± 4 18 ± 4
Dataset 18 385 10.0 46.3 ± 0.6 12.4 ± 0.7 7 88 46.3 ± 0.6 12.4 ± 0.7 DLP printer Low force micrometer ± 0.1
Dataset 19 385 5.0 310 ± 20 12 ± 2 70 290 DLP printer Calipers Unknown
Dataset 20 385 5.0 37 ± 2 4.6 ± 0.9 68 95 37 4.632 DLP printer Digital thickness gauge Uknown
Dataset 21 385 4.74 42 ± 5 10 ± 5 34 86 43 10.3 DLP printer Calipers Unknown
Dataset 22 385 5.0 51.2 ± 0.4 10.1 ± 0.4 14 179 51.2 10.1 DLP printer Dial micrometer ± 1
Dataset 23 385 5.03 56 ± 2 22 ± 5 15 174 56 21.5 DLP printer Calipers Unknown
Dataset 24 385 100 48.2 ± 0.4 7.4 ± 0.3 11.908 209.613 47.93
48.52
7.40
7.41
DLP printer LSCMh ± < 0.05
Dataset 25 388.5g 0.9 – 3.2 62 ± 1 21 ± 2 60.7 143.5 63 ± 2 21 ± 1 DLP printer Micrometer Unknown
Dataset 26 385 5.0 47 ± 2 13 ± 3 33 148 47 12.598 DLP printer Dial micrometer ± 1
Dataset 27 385 0.85 – 27.1 100 ± 10 20 ± 10 47 439 Projector
Dataset 28 385 10.37 60 ± 2 15 ± 3 35 285 60 ± 5 0.86 ± 0.02 DLP printer Micrometer Unknown
Average 385 e 80 ± 80 13 ± 6 33 192
Aggregate 385 f 55 ± 2 12 ± 2
Dataset 29 365 6.48 110 ± 20 13 ± 9 39 535 203 13.931 Independent LED Optical profilometer ± 1
Dataset 30 365 3.131 37 ± 1 13 ± 2 66 94 36.93 12.789 DLP printer Micrometer Unknown
Dataset 31 365 4.688 32 ± 1 8 ± 1 70 94 32.12 8.089 DLP printer Micrometer Unknown
Dataset 32 365 9.96 34.1 ± 0.4 3.5 ± 0.2 81 129 34.14 3.550 DLP printer Micrometer Unknown
Dataset 33 365 13.34 60 ± 3 6 ± 1 58.838 206.97 5.89 59.367 Top-down Independent LED Stylus profilometer ± < 0.05
Dataset 34 365 6.95 32 ± 2 2.1 ± 0.4 42.148 150.83 2.11 32.122 Top-down Independent LED Stylus profilometer ± < 0.05
Average 365 e 50 ± 30 8 ± 5 60 202
Aggregate 365 f 50 ± 8 9 ± 7
Dataset 35 Broad Spectrum Unknown 97 ± 1 11.0 ± 0.7 160 299 97 11.0 Mercury lamp Digital micrometer ± 3
a)

Nominal unless otherwise reported.

b)

Minimum measured cure depth.

c)

Maximum measured cure depth.

d)

Participant-reported fit parameters and uncertainty, if provided.

e)

Unweighted arithmetic mean of reported fit parameters from participants. Uncertainty is standard deviation of fit parameters.

f)

Data reported from pooling and fitting all datasets within a wavelength.

g)

Wavelength measured and reported by participant.

h)