Table 1.
λa (nm) | Irradiance (mW cm−2) | Dp (μm) | Ec (mJ cm−2) | Cd,minb (μm) | Cd,maxc (μm) | Dp,reportedd (μm) | Ec,reportedd (mJ cm−2) | Light Source | Thickness Measurement | Thickness Precision (μm) | |
---|---|---|---|---|---|---|---|---|---|---|---|
Dataset 1 | 405 | 10.0 | 70 ± 2 | 20 ± 3 | 5 | 102 | 70 ± 2 | 20 ± 3 | DLP printer | Low force micrometer | ± 0.1 |
Dataset 2 | 405 | 5.36 | 69 ± 4 | 10 ± 3 | 60 | 160 | 69 | 9.951 | Top-down light exposure | Digital thickness gauge | ± 25 |
Dataset 3 | 405 | 1.987 | 167 ± 5 | 50 ± 9 | 68 | 329 | 168 | 50.486 | DLP printer | Micrometer | ± 1 |
Dataset 4 | 405 | Unknown | 108 ± 3 | 26 ± 5 | 40 | 320 | 116.3 | 30.0 | SLA printer | Calipers | Unknown |
Dataset 5 | 405 | 12 | 134 ± 7 | 50 ± 20 | 32 | 184 | 127 ± 10 | 45 ± 6 | Laser | Not reported | |
Dataset 6 | 405 | 6.96 | 119 ± 8 | 40 ± 20 | 17.50 | 286.14 | 121 ± 4 | 40 ± 2 | Filtered broadband UV lamp | Rheometer | Unknown |
Dataset 7 | 405 | 21 | 71 ± 2 | 20 ± 2 | 46.94 | 109.51 | 70.825 | 20.284 | DLP printer | LSCMh | ± < 0.05 |
Dataset 8 | 405 | 9.231 | 169 ± 5 | 40 ± 7 | 24.13 | 560.07 | 132 | 33.476 | DLP printer | Micrometer | Unknown |
Dataset 9 | 405 | 10.0 | 93 ± 3 | 19 ± 3 | 18 | 309 | 95.3 | 20.2 | DLP printer | Dial micrometer | ± 1 |
Dataset 10 | 405 | 3.031 | 112 ± 4 | 27 ± 5 | 64 | 250 | 113.85 | 26.811 | LCD printer | Micrometer | Unknown |
Dataset 11 | 405 | 10.33 | 109 ± 9 | 16 ± 6 | 57.5 | 162.5 | 109 ± 9 | 16 ± 2 | DLP printer | Digital caliper | Unknown |
Dataset 12 | 405 | 8.22 | 119 ± 8 | 18 ± 6 | 50.0 | 145.0 | 119 ± 8 | 18 ± 1 | DLP printer | Digital caliper | Unknown |
Dataset 13 | 405 | 6.15 | 90 ± 10 | 14 ± 7 | 57.5 | 110.0 | 92 ± 10 | 14 ± 2 | DLP printer | Digital caliper | Unknown |
Dataset 14 | 405 | 402–1660 | 190 ± 20 | 700 ± 500 | 50 | 575 | 173.7 201.5 |
625.9 698.9 |
Top-down LED spot curing system | Calipers | Unknown |
Dataset 15 | 405 | 2.7 | 89 ± 6 | 18 ± 6 | 0 | 244 | 89 | 18.376 | LCD printer | Dial micrometer | ± 1 |
Dataset 16 | 405 | 63.9 | 156 ± 7 | 9 ± 2 | 346.8 | 736.7 | 155.77 | 8.54 | Top-down Independent LED | Stylus profilometer | ± < 0.05 |
Dataset 17 | 405 | 32.34 | 136 ± 6 | 17 ± 5 | 81.3 | 436.5 | 136.34 | 17.45 | Top-down Independent LED | Stylus profilometer | ± < 0.05 |
Average 405 e | 120 ± 40 | 60 ± 160 | 58 | 295 | |||||||
Aggregate 405 f | 89 ± 4 | 18 ± 4 | – | – | |||||||
Dataset 18 | 385 | 10.0 | 46.3 ± 0.6 | 12.4 ± 0.7 | 7 | 88 | 46.3 ± 0.6 | 12.4 ± 0.7 | DLP printer | Low force micrometer | ± 0.1 |
Dataset 19 | 385 | 5.0 | 310 ± 20 | 12 ± 2 | 70 | 290 | – | – | DLP printer | Calipers | Unknown |
Dataset 20 | 385 | 5.0 | 37 ± 2 | 4.6 ± 0.9 | 68 | 95 | 37 | 4.632 | DLP printer | Digital thickness gauge | Uknown |
Dataset 21 | 385 | 4.74 | 42 ± 5 | 10 ± 5 | 34 | 86 | 43 | 10.3 | DLP printer | Calipers | Unknown |
Dataset 22 | 385 | 5.0 | 51.2 ± 0.4 | 10.1 ± 0.4 | 14 | 179 | 51.2 | 10.1 | DLP printer | Dial micrometer | ± 1 |
Dataset 23 | 385 | 5.03 | 56 ± 2 | 22 ± 5 | 15 | 174 | 56 | 21.5 | DLP printer | Calipers | Unknown |
Dataset 24 | 385 | 100 | 48.2 ± 0.4 | 7.4 ± 0.3 | 11.908 | 209.613 | 47.93 48.52 |
7.40 7.41 |
DLP printer | LSCMh | ± < 0.05 |
Dataset 25 | 388.5g | 0.9 – 3.2 | 62 ± 1 | 21 ± 2 | 60.7 | 143.5 | 63 ± 2 | 21 ± 1 | DLP printer | Micrometer | Unknown |
Dataset 26 | 385 | 5.0 | 47 ± 2 | 13 ± 3 | 33 | 148 | 47 | 12.598 | DLP printer | Dial micrometer | ± 1 |
Dataset 27 | 385 | 0.85 – 27.1 | 100 ± 10 | 20 ± 10 | 47 | 439 | – | – | Projector | ||
Dataset 28 | 385 | 10.37 | 60 ± 2 | 15 ± 3 | 35 | 285 | 60 ± 5 | 0.86 ± 0.02 | DLP printer | Micrometer | Unknown |
Average 385 e | 80 ± 80 | 13 ± 6 | 33 | 192 | |||||||
Aggregate 385 f | 55 ± 2 | 12 ± 2 | – | – | |||||||
Dataset 29 | 365 | 6.48 | 110 ± 20 | 13 ± 9 | 39 | 535 | 203 | 13.931 | Independent LED | Optical profilometer | ± 1 |
Dataset 30 | 365 | 3.131 | 37 ± 1 | 13 ± 2 | 66 | 94 | 36.93 | 12.789 | DLP printer | Micrometer | Unknown |
Dataset 31 | 365 | 4.688 | 32 ± 1 | 8 ± 1 | 70 | 94 | 32.12 | 8.089 | DLP printer | Micrometer | Unknown |
Dataset 32 | 365 | 9.96 | 34.1 ± 0.4 | 3.5 ± 0.2 | 81 | 129 | 34.14 | 3.550 | DLP printer | Micrometer | Unknown |
Dataset 33 | 365 | 13.34 | 60 ± 3 | 6 ± 1 | 58.838 | 206.97 | 5.89 | 59.367 | Top-down Independent LED | Stylus profilometer | ± < 0.05 |
Dataset 34 | 365 | 6.95 | 32 ± 2 | 2.1 ± 0.4 | 42.148 | 150.83 | 2.11 | 32.122 | Top-down Independent LED | Stylus profilometer | ± < 0.05 |
Average 365 e | 50 ± 30 | 8 ± 5 | 60 | 202 | |||||||
Aggregate 365 f | 50 ± 8 | 9 ± 7 | – | – | |||||||
Dataset 35 | Broad Spectrum | Unknown | 97 ± 1 | 11.0 ± 0.7 | 160 | 299 | 97 | 11.0 | Mercury lamp | Digital micrometer | ± 3 |
Nominal unless otherwise reported.
Minimum measured cure depth.
Maximum measured cure depth.
Participant-reported fit parameters and uncertainty, if provided.
Unweighted arithmetic mean of reported fit parameters from participants. Uncertainty is standard deviation of fit parameters.
Data reported from pooling and fitting all datasets within a wavelength.
Wavelength measured and reported by participant.
Laser scanning confocal microscopy.