Original and corrected estimates for main effects from Supplement C.

Old estimate New estimate
Heat day Estimate 2.5% 97.5% p Estimate 2.5% 97.5% p
Minimum temperature cutoff for extreme heat = 85th percentile
Any day 1.0109 1.0080 1.0138  < 0.05 1.0117 1.0084 1.0149 < 0.05
1st day 1.0069 1.0030 1.0109  < 0.05 1.0080 1.0037 1.0122 < 0.05
2nd day 1.0124 1.0077 1.0171  < 0.05 1.0135 1.0085 1.0186 < 0.05
3rd day 1.0079 1.0024 1.0133  < 0.05 1.0086 1.0028 1.0145 < 0.05
Minimum temperature cutoff for extreme heat = 90th percentile
Any day 1.0132 1.0100 1.0164  < 0.05 1.0128 1.0093 1.0163 < 0.05
1st day 1.0108 1.0065 1.0151  < 0.05 1.0096 1.0049 1.0142 < 0.05
2nd day 1.0080 1.0028 1.0133  < 0.05 1.0091 1.0035 1.0148 < 0.05
3rd day 1.0134 1.0070 1.0199  < 0.05 1.0146 1.0076 1.0215 < 0.05
Minimum temperature cutoff for extreme heat = 99th percentile
Any day 1.0217 1.0143 1.0292  < 0.05 1.0211 1.0130 1.0293 < 0.05
1st day 1.0181 1.0092 1.0271  < 0.05 1.0176 1.0080 1.0273 < 0.05
2nd day 1.0227 1.0081 1.0376  < 0.05 1.0193 1.0036 1.0353 < 0.05
3rd day 1.0501 1.0238 1.0771  < 0.05 1.0623 1.0336 1.0917 < 0.05