Skip to main content
. 2024 Mar 25;9(13):15165–15174. doi: 10.1021/acsomega.3c09490

Table 2. Operation Conditions of C-101 and C-102.

compressor type centrifugal (C-101) centrifugal (C-102)
inlet pressure (bar) 1 5.7
outlet pressure (bar) 5.7 40
inlet temperature (°C) 25 17
outlet temperature (°C) 221.33 238.83
efficiency ηeff 0.97 0.97
actual power (kW) 3570.90 1411.03
theoretical power (kW) 3463.77 1368.70
Cp/Cv 1.401 1.410
calculated head (adiabatic) (m) 19682.70 22186.92