Skip to main content
. 2024 Mar 25;9(13):15165–15174. doi: 10.1021/acsomega.3c09490

Table 5. Unit Operation Table for Inlet and Outlet Streams of Tower from the Simulation Program.

tower type trayed tower type trayed tower type trayed tower type trayed
number of stages 60 number of stages 30 number of stages 191 number of stages 22
1st feed stage 50 feed stage 12 feed stage 141 feed stage 7
2nd feed stage 58 draw stage for gas stream 19 column ressure (bar) 1.3 column pressure (bar) 1.3
column pressure (bar) 5.3 column pressure (bar) 1.4 calculated reflux ratio 35 calculated reflux ratio 6
calculated reflux ratio 1.2 calculated reflux ratio 11.6 estimated top temperature (°C) –183.47 estimated top temperature (°C) –193.42
estimated top temperature (°C) –176.17 estimated top temperature (°C) –192.59 estimated bottom temperature (°C) –180.84 estimated bottom temperature (°C) –183.45
estimated bottom temperature (°C) –174.54 estimated bottom temperature (°C) –180.07 calculated condenser duty (MJ/h) –4266.95 calculated condenser duty (MJ/h) –50.216
calculate condenser duty (MJ/h) –9908.28 calculated condenser duty (MJ/h) –57686.42     calculated reboiler duty (MJ/h) 50.210
calculated reboiler duty (MJ/h) 6190.27 calculated reboiler duty (MJ/h) 57946.25