Table S2:
PSA Plant Capacity (LPM) | Refilling Capacity (JC/day)* | Refilling Booster Capacity (kWh)† |
---|---|---|
100 | 15 | 2.5 |
200 | 31 | 5 |
400 | 62 | 10 |
500 | 77 | 12.5 |
800 | 123 | 20 |
1000 | 154 | 25 |
1200 | 185 | 30 |
1500 | 231 | 35 |
2000 | 309 | 50 |
2500 | 386 | 60 |
3200 | 494 | 80 |
*The cylinder refilling capacity (jumbo cylinders (JC)/day) may vary marginally among various PSA plant models. In this study, the refilling capacity has been assumed to be 75% of the total PSA plant capacity. †The refilling booster capacity (kWh) may vary marginally among various PSA plant models. JC – Jumbo Cylinders; PSA – Pressure Swing Adsorption; LPM – Litres Per Minute