Skip to main content
. 2024 Mar 13;68(4):374–379. doi: 10.4103/ija.ija_335_23

Table S5:

PSA plants' number of hours of operation on electricity and DG set for their cost-effective utilisation

PSA plant capacity (LPM) Minimum no. of h/day when used only with electricity Maximum no. of h/day on DG set when used for 24 h/day Maximum no. of hours on DG set if used for 12 h/day



Manufacturing (h/day) Manufacturing + Cylinder Refilling (h/day) Manufacturing (h/day) Manufacturing + Cylinder Refilling (h/day) Manufacturing (h/day) Manufacturing + Cylinder Refilling (h/day)
100 10 18 2 0 0 0
200 6 10 8 1 2 0
400 5 8 8 2 3 0
500 5 8 8 2 3 1
800 5 8 9 3 4 1
1000 5 8 9 3 4 1
1200 5 8 9 3 4 1
1500 5 8 9 3 4 1
2000 5 8 9 3 4 1
2500 5 8 9 3 4 1
3200 5 8 9 3 4 1

LPM – Litres per minute; PSA – Pressure Swing Adsorption; DG – Diesel generator