Table 5.
Subjective scoring for the whole image quality of all pulmonary nodules among ASIR-V and DLIR under different radiation doses
| Variables | SDCT | LDCT | DLIR-M | DLIR-H | P | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| P | SDCT vs DLIR-H | SDCT vs DLIR-M | SDCT vs LDCT | DLIR-H vs DL-M | DLIR-H vs LDCT | DLIR-M vs LDCT | |||||
| Morphological display of nodules | 4.37 ± 0.49 | 2.71 ± 0.51 | 3.37 ± 0.49 | 4.32 ± 0.52 | <0.001 | 0.66 | <0.001 | <0.001 | <0.001 | <0.001 | <0.001 |
| Visibility for surrounding lung tissue | 4.41 ± 0.50 | 2.44 ± 0.55 | 3.24 ± 0.58 | 4.29 ± 0.56 | <0.001 | 0.32 | <0.001 | <0.001 | <0.001 | <0.001 | <0.001 |
| Artifacts and diagnostic confidence | 4.36 ± 0.49 | 2.46 ± 0.55 | 3.34 ± 0.62 | 4.27 ± 0.50 | <0.001 | 0.41 | <0.001 | <0.001 | <0.001 | <0.001 | <0.001 |
ASIR, adaptive statistical iterative reconstruction; DLIR, deep learning image reconstruction; DLIR-H: DLIR-H with low-dose; DLIR-M: DLIR-M with low-dose; LDCT: ASIR-V40% with low-dose;LDCT, low-dose CT; SD, standard deviation; SDCT, standard-dose CT; SDCT: ASIR-V40% with standard-dose.