Table 3. The proportion of the 50 validation trials with cost less than the acceptable cost of 0.2 for different detector types, signal models, and SNRs.

The cells with proportions greater or equal to 0.8 are highlighted in gray.

Signal Model Gaussian Laplacian Biophysical Average
SNR 0 dB -3 dB 0 dB -3 dB 0 dB -3 dB 0 dB -3 dB
RMS 0.34 0 0.12 0.02 0.84 0.7 0.43 0.24
Hodges 0.32 0.26 0.28 0.02 0.76 0.5 0.45 0.26
Modified Hodges 0.86 0.4 0.82 0.06 1 0.84 0.89 0.43
AGLR-G 0.82 0.56 0.76 0.16 0.7 0.6 0.76 0.44
AGLR-L 0.8 0.54 0.68 0.22 0.68 0.44 0.72 0.4
Fuzzy Entropy 0.86 0.02 0.54 0 0.94 0.98 0.78 0.33
Sample Entrpoy 0 0 0 0 0 0 0 0
Lidierth 0.18 0.04 0.18 0.02 0.72 0.46 0.36 0.17
Modified Lidierth 0.64 0.08 0.4 0.02 0.96 0.64 0.67 0.25
Bonato 0.54 0.02 0.08 0 0.06 0 0.23 0.01
TKEO 0.36 0.04 0.3 0 0.64 0 0.43 0.01
CWT 0 0 0 0 0 0 0 0
SSA 0 0 0 0 0 0 0 0