Testing results of the untreated pipes.

Test PVC90 PVC63
Flow (l/s) Re hf (mm) f Flow (l/s) Re hf (mm) f
1 1.53 2.31E+04 4.5 0.0257 0.47 1.02E+04 3.0 0.0305
2 1.97 2.98E+04 7.0 0.0240 0.83 1.79E+04 8.0 0.0261
3 2.44 3.69E+04 10.0 0.0223 1.17 2.51E+04 14.5 0.0241
4 2.72 4.11E+04 12.0 0.0216 1.56 3.35E+04 24.5 0.0229
5 3.06 4.62E+04 15.0 0.0215 1.83 3.94E+04 32.5 0.0219
6 3.42 5.16E+04 18.0 0.0206 2.00 4.30E+04 38.0 0.0215
7 3.71 5.60E+04 21.0 0.0204 2.39 5.14E+04 52.0 0.0206
8 4.03 6.09E+04 24.5 0.0202 2.58 5.56E+04 60.0 0.0204
9 4.69 7.09E+04 32.0 0.0194 2.89 6.22E+04 73.5 0.0199
10 5.22 7.89E+04 38.5 0.0189 3.17 6.81E+04 86.5 0.0195
11 3.44 7.41E+04 100.5 0.0192