Skip to main content
. 2024 Apr 8;14:8236. doi: 10.1038/s41598-024-59075-7

Table 2.

Testing results of the treated pipes.

Test PVC90 PVC63
Flow (l/s) Re hf (mm) f Flow (l/s) Re hf (mm) f
1 0.88 1.33E+04 1.0 0.0171 1.0 7.17E+03 1.0 0.0204
2 1.31 1.97E+04 2.5 0.0196 4.0 1.37E+04 4.0 0.0222
3 1.50 2.27E+04 3.5 0.0208 8.5 1.91E+04 8.5 0.0244
4 1.75 2.64E+04 5.0 0.0218 14.5 2.51E+04 14.5 0.0241
5 2.08 3.15E+04 7.5 0.0231 25.0 3.41E+04 25.0 0.0226
6 2.39 3.61E+04 10.0 0.0234 34.5 4.06E+04 34.5 0.0219
7 2.75 4.16E+04 12.0 0.0212 44.0 4.72E+04 44.0 0.0207
8 2.97 4.49E+04 14.0 0.0212 51.5 5.20E+04 51.5 0.0200
9 3.25 4.91E+04 17.0 0.0215 60.0 5.56E+04 60.0 0.0204
10 3.92 5.92E+04 23.0 0.0200 75.0 6.34E+04 75.0 0.0196
4.50 6.80E+04 29.5 0.0195 118.5 8.19E+04 118.5 0.0185
5.11 7.72E+04 37.0 0.0189 130.0 8.85E+04 130.0 0.0174