Skip to main content
. 2024 Apr 25;14:9495. doi: 10.1038/s41598-024-60221-4

Table 2.

Mechanical properties of TGFβ1-treated 3D tendon constructs at T14 (n = 7, value ± standard deviation).

Cross-sectional area (mm2) 0.17 ± 0.10
Max load (N) 0.43 ± 0.14
Stiffness (N/mm) 0.23 ± 0.07
Max stress (MPa) 3.52 ± 2.43
Modulus (MPa) 20.55 ± 9.92
Energy to failure (mJ) 0.50 ± 0.26
Max strain (mm/mm) 0.19 ± 0.06
Toughness (mJ/m3) 0.39 ± 0.38