Skip to main content
. 2024 May 1;9(5):2472–2483. doi: 10.1021/acsenergylett.4c00807

Table 3. Summary of the Operational Parameters of the Air Contactor and (Bi)carbonate Electrolyzere.

graphic file with name nz4c00807_0008.jpg

a

This range was calculated based on the KOH concentration range of 0.60–1.00 M to keep pHmaximum at 14.

b

This pH was calculated using our microkinetic model.

c

Taken from Keith et al.,5 assuming 70% fan efficiency and 82% pump efficiency.

d

Estimated from our electrolyzer process model, considering Vminimum = 2.5 V and Vmaximum = 3.5 V.

e

Green and red cells highlight compatibility and incompatibility, respectively. Yellow cells show an important difference between the units.