Skip to main content
. 2024 Apr 17;6(10):2669–2681. doi: 10.1039/d4na00303a

Values of diffusion coefficients and mobile charge concentration obtained at different temperature, from the peaks observed in loss tangent for the peptides NY7, GY7 and SY7, respectively.

Sample T(°C) D 1(m2 s−1) D 2(m2 s−1) n 1(m−3) n 2(m−3)
NY7 20 4.8 × 10−6 5.4 × 1019
40 6.9 × 10−6 2.9 × 10−12 1.2 × 1020 2.9 × 1026
60 7.2 × 10−6 4.1 × 10−12 1.9 × 1020 3.4 × 1026
80 1.8 × 10−6 12.2 × 10−12 4.8 × 1020 7.0 × 1025
100 3.9 × 10−7 3.9 × 1020
120 1.0 × 10−7 6.0 × 1020
140 3.4 × 10−8 1.2 × 1021
GY7 20 7.0 × 10−6 3.9 × 10−12 1.9 × 1021 3.4 × 1027
40 1.1 × 10−5 9.9 × 10−12 2.8 × 1021 3.0 × 1027
60 2.2 × 10−5 2.0 × 10−11 1.7 × 1021 1.9 × 1027
80 1.8 × 10−5 4.6 × 10−11 2.5 × 1021 9.8 × 1026
100 1.1 × 10−5 6.5 × 10−11 8.5 × 1020 1.5 × 1026
120 4.1 × 10−6 3.2 × 1019
140 3.4 × 10−8 2.4 × 1020
SY7 20 3.2 × 10−7 8.8 × 1023
40 7.8 × 10−7 1.0 × 1023
60 1.4 × 10−6 5.7 × 1022
80 2.1 × 10−6 5.6 × 10−11 3.4 × 1022 1.9 × 1026
100 2.2 × 10−6 7.0 × 10−11 2.2 × 1025 6.0 × 1025
120 1.1 × 10−7 1.2 × 10−10 2.5 × 1025 6.1 × 1025