Skip to main content
. 2024 May 9;73(18):411–416. doi: 10.15585/mmwr.mm7318a1

TABLE. Environmental testing results of a Shiga toxin–producing Escherichia coli O157:H7 outbreak investigation — city A, Utah, July–August 2023.

Site* Grab water samples (MPN/100 mL)
Dead-end ultrafiltration water samples
Total coliforms E. coli Microbial source tracking§ E. coli O157:H7
Exposure site A
<1
<1
Avian: detected
Detected
Ruminant: ND
Human: ND
Exposure site C
344.8
5.1
Avian: detected
Detected
Ruminant: detected
Human: ND
Exposure site D
866.4
8.5
Avian: detected
Detected
Ruminant: ND
Human: ND
Exposure sites E and F
5.2
<1
Avian: detected
ND
Ruminant: ND
Human: ND
Exposure site G
NC
NC
Avian: detected
Detected
Ruminant: detected
Human: detected
Exposures site H
686.7
3.1
Avian: detected
ND
Ruminant: detected
Human: ND
Exposure site I
<1
<1
Avian: detected
Detected
Ruminant: detected
Human: ND
Exposure site J
285.1
4.1
Avian: detected
ND
Ruminant: detected
Human: ND
Exposure site K
228.2
10.8
Avian: detected
ND
Ruminant: detected
Human: ND
City A UPMIW reservoir
Grab #1: 33.1
Grab #1: 2.0
Avian: detected
ND
Grab #2: 613.1
Grab #2: 9.6
Ruminant: ND
Human: ND
City A UPMIW reservoir sediment #1
NA
NA
Avian: detected
ND
Ruminant: ND
Human: ND
City A UPMIW reservoir sediment #2 NA NA Avian: detected
Detected
Ruminant: ND
Human: ND

Abbreviations: E. coli = Escherichia coli; MPN = most probable number; NA = not applicable; NC = not collected; ND = not detected; UPMIW = untreated, pressurized, municipal irrigation water.

* Exposure sites A–K were named based on the location of each ill person’s reported UPMIW exposure.

Total coliforms and E. coli (fecal indicator bacteria) were measured using Environmental Protection Agency standard methods, IDEXX Colilert-18 or Enterolert, on 100-mL grab water samples paired with dead-end ultrafiltration water samples. Sediment was not tested for total coliforms and E. coli.

§ Microbial source tracking assays were conducted using methods described in https://journals.asm.org/doi/10.1128/aem.04137-13, https://academic.oup.com/jambio/article/108/3/974/6720002?login=true, and https://www.frontiersin.org/articles/10.3389/fsufs.2019.00124/full.

Detection of E. coli O157:H7 in environmental samples was determined using methods from https://assets.publishing.service.gov.uk/media/5be99537ed915d6a203046fd/SCA_Blue_Book_236.pdf, https://assets.publishing.service.gov.uk/media/5be9964e40f0b667b363e25d/MoDWPart4-223MAYh.pdf, and https://pubmed.ncbi.nlm.nih.gov/19363065/.

** A grab water sample was not collected at exposure site G.