Table 3.
Study on the effect of acupuncture Deqi on target organ.
| Acupoints | Research content | Instruments | Results | References |
|---|---|---|---|---|
| ST36 | DM | Electrocardiograph | Lifting-thrusting and twirling: blood pressure and heart rate↓. | Huang et al., 2012c |
| ST36, PC6 | DQ-NR | Impedance blood-diagram-scope, Gastrointestinal electrograph | Change gastroelectric wave parameters. | Huang, 1999 |
| PC6 | DQ-CS | Electrophysiolograph | Change cardiac output SV, CO, ST segment, and electrocardiogram T-wave. | You et al., 1992 |
| LI4, LI11 | DQ-SA | Blood pressure monitor, Electrocardiogram | Heart rate, mean arterial pressure and LF/HF values of heart rate variability↑. | Yu and Jones, 2013 |
DM, Different manipulation; DQ, Deqi; NR, no reaction; CS, complex sensation; SA, Sham Acupuncture.