Skip to main content
. 2024 May 3;18:1386108. doi: 10.3389/fnins.2024.1386108

Table 3.

Study on the effect of acupuncture Deqi on target organ.

Acupoints Research content Instruments Results References
ST36 DM Electrocardiograph Lifting-thrusting and twirling: blood pressure and heart rate↓. Huang et al., 2012c
ST36, PC6 DQ-NR Impedance blood-diagram-scope, Gastrointestinal electrograph Change gastroelectric wave parameters. Huang, 1999
PC6 DQ-CS Electrophysiolograph Change cardiac output SV, CO, ST segment, and electrocardiogram T-wave. You et al., 1992
LI4, LI11 DQ-SA Blood pressure monitor, Electrocardiogram Heart rate, mean arterial pressure and LF/HF values of heart rate variability↑. Yu and Jones, 2013

DM, Different manipulation; DQ, Deqi; NR, no reaction; CS, complex sensation; SA, Sham Acupuncture.