Skip to main content
. 2024 May 20;15:120. doi: 10.1186/s13244-024-01679-8

Table 4.

Comparison of performance between the hybrid model and staging systems on the validation Set (n = 129)

Performance Hybrid model BCLC system p value CNLC system p value
C-index 0.706 (0.630, 0.783) 0.543 (0.494, 0.592) < 0.001 0.630 (0.557, 0.703) 0.061
6-month tdAUC 0.710 (0.579, 0.842) 0.557 (0.488, 0.627) 0.005 0.711 (0.590, 0.832) 0.992
12-month tdAUC 0.739 (0.638, 0.840) 0.554 (0.490, 0.618) < 0.001 0.710 (0.610, 0.811) 0.635
18-month tdAUC 0.732 (0.634, 0.830) 0.553 (0.492, 0.614) < 0.001 0.654 (0.561, 0.748) 0.166
24-month tdAUC 0.743 (0.653, 0.834) 0.550 (0.489, 0.611) < 0.001 0.635 (0.547, 0.723) 0.032

Statistically significant p values are bold

Data in parentheses are 95% confidence intervals