Table 9.
Diagnostic accuracy results and all optimal cut-off points of BioPMovQ.
Subclinical | Moderate | Severe | |
---|---|---|---|
Mean ± SD | 30.73 ± 8.03 | 36.85 ± 9.27 | 47.49 ± 8.15 |
95% CI | [28.91–32.54] | [34.16–39.86] | [45.56–49.42] |
Median (25th percentile; 75th percentile) | 30 (P25 = 25; P75 = 38) | 36 (P25 = 29.25; P75 = 44) | 49 (P25 = 42; P75 = 53) |
Cases, N (%) | 78 (39.59%) | 48 (24.37%) | 71 (36.04%) |
Optimal cuff-off point | <37 | ≥37 | ≥45 |
Sensitivity (95% CI) | – | 0.87 [0.76–0.84] | 0.72 [0.61–0.82] |
Specificity (95% CI) | – | 0.59 [0.44–0.62] | 0.98 [0.92–1] |
Positive predictive value (95% CI) | – | 0.73 [0.61–0.75] | 0.98 [0.90–0.98] |
Negative predictive value (95% CI) | – | 0.78 [0.62–0.74] | 0.78 [0.68–0.99] |
SD, standard deviation; 95% CI, confidence interval.