Skip to main content
. 2024 May 14;16(10):1869. doi: 10.3390/cancers16101869

Table 6.

Pelvic MRI Protocol.

Series Description Slice Thickness
(mm)
Inter-Slice Gap (mm) FOV Acquisition Time (min) Frequency Encoding Direction Acquired Matrix (Frequency × Phase) b-Value (s/mm2) Coverage
Coronal T2 weighted single-shot FSE (to include the kidneys) 5 0 420 1.4 Superior–inferior 288 × 192 Entire pelvis to include the kidneys
Sagittal T2 weighted (FSE) 5 0 240 2 Anterior–posterior 320 × 224 Entire uterus, cervix
Sagittal restricted—FOV DW images with spin echo 5 0 240 16 Superior–inferior 96 × 80 50, 600 Entire uterus, cervix
Axial T2 weighted FSE 5 0 240 2 Left–right 320 × 224 Entire pelvis
Axial T1 weighted FSE 5 0 240 2 Left–right 320 × 224 Entire pelvis
Axial DW images with spin echo 5 0 380 8 Left–right 96 × 160 50, 400, 800 Entire pelvis
Axial 3D unenhanced T1-weighted spoiled gradient-recalled echo with fat suppression 5 −2.5 240 1 Left–right 320 × 224 Entire pelvis
Sagittal T1-weighted dynamic contrast-enhanced spoiled gradient-recalled echo with fat suppression 5 −2.5 240 1 Superior–inferior 256 × 224 Entire uterus, cervix
Three-dimensional contrast-enhanced T1-weighted spoiled gradient-recalled echo with fat suppression 5 −2.5 240 1 Left–right 320 × 224 Entire pelvis