Skip to main content
. 2023 Nov 7;34(5):2895–2904. doi: 10.1007/s00330-023-10373-0

Table 3.

Detailed metrics for the receiver operating characteristic analysis of the best model MS/G trained with all available data on both test sets with report and image-based labels. The area under the receiver operating characteristic curve (AUC) in % is given per class. Also, sensitivity and specificity in % are given per class for binary classifications. Thresholds were calculated by the Youden-Index on the training set and applied to the test set

Test-set labeled by report content Test-set labeled by image content
Classes AUC Sensitivity Specificity AUC Sensitivity Specificity
Misplaced CVC 77.6 64.4 74.1 83.4 70.5 76.9
Pleural Effusion 86.4 71.9 83.3 87.5 73.5 83.8
Pulmonary Congestion 74.5 57.8 75.9 83.9 60.2 88.1
Pulmonary Infiltrates 81.9 78.3 70.7 77.3 77.8 66.9
Pneumothorax 84.0 87.8 60.6 91.8 97.1 60.1
Overall 80.9 72.0 72.9 84.8 75.8 75.2