Table 3. Tukey’s HSD post hoc test for multiple comparisons.
*Significant difference (P<0.05). HSD: Honest Significant Difference
| Material | Variable | Technique (A) | Technique (B) | Mean difference (A-B) | P |
| Polyvinyl siloxane | Error rate for angulated implants (%) | Closed tray | Open tray | 0.6551 | 0.006* |
| Closed tray | Open tray with sandblasting and adhesive coating of impression copings | 0.8294 | 0.001* | ||
| Open tray | Open tray with sandblasting and adhesive coating of impression copings | 0.1744 | 0.641 | ||
| Vinylsiloxanether | Error rate for parallel implants (%) | Closed tray | Open tray | 0.2508 | 0.073 |
| Closed tray | Open tray with sandblasting and adhesive coating of impression copings | 0.4081 | 0.002* | ||
| Open tray | Open tray with sandblasting and adhesive coating of impression copings | 0.1573 | 0.333 |