Table 8. Defined Operating Conditions for Different Units.

unit number type of aspen model Toperating (°C) Poperating (bar) other specifications
P-101 pump   10  
E-101 heatX 316   cold stream outlet
E-102 heater 316 10  
R-101 RStoic   10 adiabatic
E-103 heater 400 10  
R-101–2 RStoic 400 10  
C-100 compressor   20 isentropic
R-102 RPlug 400 20 isothermal
R-103 RPlug 400 20 isothermal
R-104 RPlug 400 20 isothermal
E-104 heatX     5 K hot/cold out temp. appr.
E-105 heater 100 20  
E-106 heater 70 20  
E-107 heater 30 20  
V-100 valve   15 adiabatic flash
S-101 flash3   15 adiabatic
C-101 compressor   21 isentropic
E-108 heater 40 15  
V-105 valve   5 adiabatic flash
E-109 heater 50 5  
V-106 valve   1 adiabatic flash
E-110 heater 60 1  
P-102 pump   16  
E-111 heatX 150   cold stream out temp. increase
E-112 heater 345 16  
R-105 RStoic 345 16 isothermal
E-113 heater 135 16  
E-114 heater 80 16  
E-115 heater 30 16  
S-102 flash2 30 16  
C-102 turbine   16 isentropic
E-116 heater 345 16  
E-117 heater 60 16  
E-118 heater 25 1  
S-103 flash2 25 1 isothermal