Table 8. Defined Operating Conditions for Different Units.
| unit number | type of aspen model | Toperating (°C) | Poperating (bar) | other specifications |
|---|---|---|---|---|
| P-101 | pump | 10 | ||
| E-101 | heatX | 316 | cold stream outlet | |
| E-102 | heater | 316 | 10 | |
| R-101 | RStoic | 10 | adiabatic | |
| E-103 | heater | 400 | 10 | |
| R-101–2 | RStoic | 400 | 10 | |
| C-100 | compressor | 20 | isentropic | |
| R-102 | RPlug | 400 | 20 | isothermal |
| R-103 | RPlug | 400 | 20 | isothermal |
| R-104 | RPlug | 400 | 20 | isothermal |
| E-104 | heatX | 5 K hot/cold out temp. appr. | ||
| E-105 | heater | 100 | 20 | |
| E-106 | heater | 70 | 20 | |
| E-107 | heater | 30 | 20 | |
| V-100 | valve | 15 | adiabatic flash | |
| S-101 | flash3 | 15 | adiabatic | |
| C-101 | compressor | 21 | isentropic | |
| E-108 | heater | 40 | 15 | |
| V-105 | valve | 5 | adiabatic flash | |
| E-109 | heater | 50 | 5 | |
| V-106 | valve | 1 | adiabatic flash | |
| E-110 | heater | 60 | 1 | |
| P-102 | pump | 16 | ||
| E-111 | heatX | 150 | cold stream out temp. increase | |
| E-112 | heater | 345 | 16 | |
| R-105 | RStoic | 345 | 16 | isothermal |
| E-113 | heater | 135 | 16 | |
| E-114 | heater | 80 | 16 | |
| E-115 | heater | 30 | 16 | |
| S-102 | flash2 | 30 | 16 | |
| C-102 | turbine | 16 | isentropic | |
| E-116 | heater | 345 | 16 | |
| E-117 | heater | 60 | 16 | |
| E-118 | heater | 25 | 1 | |
| S-103 | flash2 | 25 | 1 | isothermal |