Setting PEEP in the Severely Obstructive Patient

Amal Jubran 1
PMCID: PMC11141232  NIHMSID: NIHMS1949134  PMID: 38085854

Abstract

Purpose of review:

The response to positive end-expiratory pressure (PEEP) in patients with chronic obstructive pulmonary disease (COPD) requiring mechanical ventilation depends on the underlying pathophysiology. This review focuses on the pathophysiology of COPD, especially intrinsic PEEP (PEEPi) and its consequences, and the benefits of applying external PEEP during assisted ventilation when PEEPi is present

Recent findings:

The presence of expiratory airflow limitation and increased airway resistance promotes the development of dynamic hyperinflation in patients with COPD during acute respiratory failure. Dynamic hyperinflation and the associated development of PEEPi increases work of breathing and contributes to ineffective triggering of the ventilator. In the presence of airflow limitation, application of external PEEP during patient-triggered ventilation has been shown to reduce inspiratory effort, facilitate ventilatory triggering and enhance patient-ventilator interaction. To minimizes the risk of hyperinflation, it is advisable to limit the level of external PEEP during assisted ventilation after optimization of ventilator settings to about 70% of the level of PEEPi (measured during passive ventilation).

Summary:

In patients with COPD and dynamic hyperinflation receiving assisted mechanical ventilation, the application of low levels of external PEEP can minimize work of breathing, facilitate ventilator triggering and improve patient-ventilator interaction.

Keywords: COPD, dynamic hyperinflation, external PEEP, intrinsic PEEP

Introduction

Exacerbations of chronic obstructive pulmonary disease (COPD) are one of the main indications for receiving mechanical ventilation worldwide (1, 2). Although mechanical ventilation is two to four times more likely to be initiated in patients with COPD than in patients with adult respiratory distress syndrome (ARDS) (1, 2), most of the recent literature on the delivery of mechanical ventilation has focused primarily on ARDS and not COPD (3–5).

Positive end-expiratory pressure (PEEP) is an intervention that can be applied to all modes of mechanical ventilation. The response to PEEP in ventilated patients with COPD, however, depends on the underlying pathophysiology. This review focuses on the pathophysiology of airway obstruction in COPD, especially the development of dynamic hyperinflation and intrinsic PEEP (PEEPi), during acute respiratory failure. The benefits of adding external PEEP during assisted ventilation in the presence of PEEPi will also be discussed.

Pathophysiology of airflow obstruction

EXPIRATORY AIRFLOW LIMITATION AND DYNAMIC HYPERINFLATION

In stable patients with COPD, inspiratory flow resistance is approximately 6 cm H2O/L/sec above normal (6). During an episode of acute respiratory failure, resistance can increase by as much 13 cm H2O/L/sec (7). Expiratory resistance in markedly increased in patients with COPD (8). In ventilated patients with COPD, the ratio of expiratory to inspiratory flow resistance ranges from 3.8 at low lung volumes to 1.6 at high lung volumes (9, 10).

The main problem in COPD is not only the increase in airway resistance per se, but also expiratory airflow limitation. Expiratory flow limitation refers to a condition in which expiratory flow cannot increase as a result of decreased tethering of the airways secondary to rupture of elastic fibers (10).

Expiratory airflow limitation occurs in about 60% of stable patients with COPD (11) and is universally present during episodes of acute respiratory failure (12).

The minimum time required to exhale from a given lung volume to relaxation volume of the respiratory system is determined by the maximum expiratory flow (10). The amount of time taken by lung units to empty during exhalation, referred to as time constant of the respiratory system, is calculated as the product of compliance and resistance. One time constant indicates the time required to empty 63% of the volume inhaled and three time constants represents the time required to empty 95% of the volume inhaled. When the time for expiration is less than minimum time required for exhalation, inspiration will begin before the respiratory system has returned to its relaxation volume– a state known as dynamic hyperinflation. When patients with severe COPD and expiratory flow limitation develop tachypnea, they necessarily shorten the time available for expiration (expiratory time). The decrease in expiratory time means that the next inspiration will begin before the respiratory system has returned to its relaxation volume, thus producing dynamic hyperinflation. In addition to flow limitation, increased airway resistance also contributes to dynamic hyperinflation. Increased airway resistance will increase the time constant; the higher the time constant, the longer the time required to have complete exhalation. By prolonging the time constant of the respiratory system, increased resistance will decrease the time needed for expiration (13).

INTRINSIC PEEP

Dynamic hyperinflation is almost consistently associated with an increase in end-expiratory elastic recoil of the respiratory system. The positive recoil pressure is referred to as auto or intrinsic PEEP (PEEPi) (14–16). PEEPi can be quantified in relaxed patients (under passive conditions) using an end-expiratory hold maneuver on a mechanical ventilator immediately before the onset of the next breath (static PEEPi) (15, 17, 18); end-expiratory occlusion allows measuring the pressure in the alveoli in the absence of complete airway collapse. PEEPi can also be quantified as a change in airway pressure needed to reduce expiratory flow to zero and initiate lung inflation by the ventilator (dynamic PEEPi) (19, 20). In patients with COPD, dynamic PEEPi is lower than static PEEPi; this discrepancy is attributed to the presence of time-constant inequalities within the lungs (21, 22).

In patients with active inspiratory muscles, measurements of static PEEPi are not reliable because patients react unpredictably to end-expiratory occlusion (23, 24) (Figure 1). When muscles are actively contracting as during assisted ventilation, measurement of dynamic PEEPi requires the insertion of balloon-tipped esophageal catheter (25, 26). Dynamic PEEPi is measured as the amount of decrease in esophageal pressure from the onset of inspiratory effort to the start of inspiratory flow (10, 25, 27) (Figure-2). This measurement of dynamic PEEPi has been used in acutely-ill patients with COPD and is valid provided that the expiratory muscles are relaxed at end-expiration. When expiratory muscles are contracting, the pressure developed in the abdomen is transmitted through the relaxed diaphragm and raises intrathoracic pressure (27–29). Accordingly, assessing PEEPi using esophageal pressure will overestimate the true end-expiratory elastic recoil pressure (28, 29).

Figure 1.

Figure 1.

Airway pressure (Paw), esophageal pressure (Pes), and gastric pressure (Pga) in a patient with COPD being ventilated with assist-control ventilation. The airway was occluded during expiration in order to quantify intrinsic PEEP (PEEPi). The patient made an expiratory effort during the occlusion (arrow), and thus the recorded pressure overestimated the true PEEPi. Reproduced from Jubran (Figure 48–14 of ref 24).

Figure 2:

Figure 2:

Flow, airway pressure (Paw), and esophageal pressure (Pes) in Patient 1 (left) and Patient 2 (right) with COPD receiving pressure support ventilation set at 20 cmH2O (no external PEEP is applied). Dynamic intrinsic PEEP, estimated as the difference in esophageal pressure between the onset of inspiratory effort (vertical blue line) and the onset of inspiratory flow (vertical red line), was 0.5 cmH2O in the patient on the left and 10.6 cm H2O in the patient on the right. Reproduced from Tobin (Figure 4 of ref 10).

CONSEQUENCES OF PEEPi

Increase in respiratory work and ineffective triggering.

Dynamic hyperinflation and PEEPi has adverse effects on pulmonary mechanics and respiratory work. In ventilator-dependent patients with COPD, PEEPi accounted for as much as 40% of overall respiratory work (30, 31). In patients with COPD recovering from an episode of respiratory failure necessitating mechanical ventilation, about 20–25% of the inspiratory muscle effort was required to overcome PEEPi during a T-piece weaning trial (7).

Hyperinflation increases work of breathing because inspiration occurs at the upper, less compliant portion of the pressure-volume curve of the lung, where inwardly directed elastic recoil of the chest wall poses an additional elastic load. The positive pressure in the alveolus at the end of expiration means that the patient has to first generate negative inspiratory pressure equal in magnitude to the opposing elastic recoil pressure (level of PEEPi) before inspiratory flow can be initiated—that is threshold inspiratory load (10). If a patient with PEEPi is triggering a ventilator, he or she has to generate a negative pressure equal in magnitude to the level of PEEPi in addition to the set minimum circuit pressure drop before a ventilator-assisted breath is initiated. This is one factor that accounts for the common occurrence of failure to trigger the ventilator despite obvious respiratory effort (32) (Figure 3).

Figure 3:

Figure 3:

Flow, airway pressure (Paw) and esophageal pressure (Pes) in a patient with COPD who is receiving assist-control ventilation at the following settings: tidal volume 600 ml, inspiratory flow 60 L/min, trigger sensitivity −2 cm H2O and positive end-expiratory pressure 0 cm H2O. The patient’s intrinsic respiratory rate is 28 breaths per minute, whereas the number of breaths delivered by the ventilator is 16 breaths per minute. That is, 43% of the patient’s inspiratory efforts fail to trigger ventilator assistance. Reproduced from Tobin (Figure 53–12 of ref 32).

In a study of factors contributing to ineffective triggering, a decrease in the magnitude of inspiratory effort at a given level of assistance was not the cause; indeed, effort was 38% higher during nontriggering attempts than during the triggering phase of attempts that successfully opened the ventilator valve (33). Significant differences, however, were noted in the characteristics of the breaths before the triggering and non-triggering attempts. Breaths before non-triggering attempts had shorter respiratory cycle times and expiratory time and higher static PEEPi than did the breaths before triggered attempts. These findings suggest that ineffective triggering did not result from a decrease in the magnitude of effort, but rather from inspiratory efforts that were premature and insufficient to overcome the elevated elastic recoil pressure associated with dynamic hyperinflation (10, 33).

In addition to an increase in elastic recoil, expiratory muscle activity can contribute to an elevated PEEPi (29, 34–36). In healthy subjects receiving pressure support ventilation in whom airflow limitation was induced with a Starling resistor (28), PEEPi was more than 30% higher at the start of nontriggering attempts than before triggering attempts—similar to the condition in critically ill patients (33). Although the elastic recoil pressure (quantified as PEEPi minus increase in gastric pressure) was higher before non-triggered attempts than triggered attempts, the level of expiratory effort (quantified the expiratory increase in gastric pressure), was similar before nontriggering and triggering attempts, indicating that expiratory effort did not contribute to generation of PEEPi. Accordingly, it is the increase in elastic recoil and not expiratory effort, that is responsible for failure to trigger the ventilator.

Respiratory muscle dysfunction.

Dynamic hyperinflation impairs respiratory muscle function by worsening the length-tension relationship of the muscles, decreasing the zone of apposition and the curvature of the diaphragm, and changing the mechanical arrangement of costal and crural components of the diaphragm (10).

Hemodynamic compromise.

Alveolar overdistension and PEEPi can severely decrease cardiac output (15) by impeding venous return and increasing right-ventricular afterload (37, 38).

Hemodynamic compromise as a result of PEEPi is more magnified in COPD because the abnormally compliant lungs transmit a high fraction of alveolar pressure to intrathoracic vessels (15). During cardiopulmonary resuscitation, PEEPi in patients with airway obstruction may cause pulseless electrical activity (39, 40).

Barotrauma.

Application of external PEEP can lead to overdistension and rupture resulting in pneumomediastinum and pneumothorax (41) not only in COPD patients but in all ventilated patients. While the same complication may occur with increased levels of PEEPi, systematic studies have not been conducted on this matter.

Errors in monitoring.

The presence of PEEPi can lead to erroneous measurements of static compliance of respiratory system, computed as tidal volume divided by plateau pressure minus set PEEP (18). PEEPi commonly goes undetected, since it is not registered on the pressure manometer of the ventilator, which is open to the atmosphere. Accordingly, in the presence of PEEPi, the total PEEP may markedly exceed the set PEEP. Failure to take PEEPi into account caused a 48% underestimation in the static compliance (19).

Use of external PEEP in COPD

In patients with COPD receiving assisted mechanical ventilation, the primary goals of PEEP are to enhance triggering sensitivity, decrease work of breathing secondary to the inspiratory threshold load effect of PEEPi, and optimize patient-ventilator interaction.

An effective approach to reduce or eliminate PEEPi is to decrease minute ventilation even if this means development of alveolar hypoventilation – permissive hypercapnia (42). In patients with COPD ventilated with assist-control ventilation, clinicians often increase inspiratory flow to decrease inspiratory time in the hope of allowing more time for expiration and thus decrease PEEPi. Because increases in flow commonly lead to an increase in respiratory rate (43), the anticipated reduction of expiratory time might increase PEEPi.

In patients with COPD while receiving assist-control ventilation, increase in flow from 30 to 90 L/minute increased the respiratory rate but decreased PEEPi (44). Decrease in PEEPi was the result of a paradoxical increase in expiratory time, which allowed more time for lung deflation. The investigators reasoned that the shortened inspiratory time combined with time-constant inhomogeneity of COPD caused over-inflation of some lung units to persist into neural exhalation. Continued inflation during neural exhalation causes stimulation of the vagus nerve, which prolongs expiratory time (44).

PHYSIOLOGICAL BENEFITS OF PEEP

Addition of external PEEP can decrease work secondary to the inspiratory threshold load effect of PEEPi (9, 30, 45). To start inspiratory flow, alveolar pressure must be lowered below ambient pressure. During normal spontaneous breathing, this is accomplished by only a small decrease in pleural pressure. For alveolar pressure to fall below ambient pressure in the presence of hyperinflation, however, a much greater decrease in pleural pressure is needed. If ambient pressure is elevated by the application of external PEEP, inspiration is more easily accomplished because alveolar pressure needs to be decreased only below the level of external PEEP (rather than below zero). This may seem paradoxical: external PEEP, which is commonly used to induce hyperinflation in patients with microatelectasis, is being used to decrease the work of breathing induced by hyperinflation (32).

This conundrum can be explained by the analogy of a waterfall (46). The height of the waterfall represents the critical closing pressure of airways in patients with COPD and PEEPi. The driving pressure for flow throughout expiration is the level of PEEPi minus critical closing pressure. Elevating downstream pressure with external PEEP, has no influence on either expiratory airflow or the pressure upstream (PEEPi) from the site of critical closure. This situation exists until downstream pressure is elevated to a value equal to the critical closing pressure. Once downstream pressure is elevated above the critical closing pressure (the height of the waterfall), however, the pressure upstream increases immediately, and hyperinflation is exacerbated (32, 46).

The application of external PEEP decreases the work of inspiration in patients with PEEPi during patient-triggered ventilation and improves patient-ventilator interaction only in the setting of airflow limitation (9, 10, 47). In patients without airflow limitation, the effective expiratory driving pressure is elastic recoil pressure minus the pressure at the airway opening. Accordingly, the application of external PEEP will decrease the expiratory driving pressure and produce a decrease in expiratory flow at all lung volumes and an increase in end -expiratory lung volume (47, 48). Adding extrinsic PEEP lower than PEEPi reduces the amount of work needed to trigger the ventilator even in the absence of airflow limitation (as long as airflow limitation means partial airway collapse).

Although external PEEP can help decrease inspiratory work, it does nothing to relieve the accompanying hyperinflation, which has other detrimental effects. It is important to keep in mind that patients with airflow limitation have heterogenous distribution of lung units, each with its own critical closing pressure. Because of the regional inhomogeneities among lung units, the average level of PEEPi must exceed the lowest regional alveolar pressure. Thus, external PEEP equal to PEEPi could cause hyperinflation in the faster-emptying lung units (49). To minimizes this risk, it is reasonable that after optimization of ventilator settings, to limit the level of external PEEP to about 70% of the level of PEEPi (measured using end-expiratory hold maneuver while patient is passively ventilated) (50). Indeed, several studies have demonstrated that titration of PEEP to about two third of the level of PEEPi reduced inspiratory effort and the number of ineffective efforts; it also facilitated ventilatory triggering by decreasing both inspiratory effort and delay between the onset of inspiratory effort and initiation of assistance. (9, 30, 45, 51).

TITRATION OF EXTERNAL PEEP

The beneficial effect of external PEEP in ventilated patients with COPD is dependent on the presence of airflow limitation and patient-triggered ventilation (37, 52, 53). Because its unpredictably on hyperinflation, the titration of external PEEP should be guided by measurement of static PEEPi (37, 54) performed during passive ventilation. When PEEPi is present, the rise in airway pressure during the occlusion maneuver at end-expiration should be maintained until a plateau is reached. In the presence of airflow limitation, titration of PEEP should continue until peak and plateau airway pressure show a sizeable increase (volume-cycled ventilation) or when tidal volume starts to decrease (pressure-cycled ventilation) (37, 53) (Figure 4).

Figure 4:

Figure 4:

Airway pressure (Paw) versus time during controlled mechanical ventilation as external positive end-expiratory pressure (PEEP) is increased from 0 to 12 cm H2O in a patient with expiratory flow limitation (upper panel) and in a patient without expiratory flow limitation (lower panel). In both patients, static intrinsic PEEP (PEEPi) (arrow) is 10 cm H2O. In the presence of expiratory flow limitation upper panel), peak airway pressure increases only when external PEEP is 12 cm H2O (dotted red line). In the absence of expiratory flow limitation (lower panel), application of external PEEP causes a proportional increase in peak airway pressure. The qualitative responses to external PEEP, seen with peak airway pressure, are expected to occur also with plateau pressure. Reproduced from Laghi (Figure 31–10 of ref 53).

Conclusion

In the past, PEEP was avoided in patients with COPD because of the fear of aggravating hyperinflation. Subsequent work indicates that the application of PEEP during assisted ventilation in patients with airflow limitation makes it easier for the patient to trigger the ventilator, thereby improving patient-ventilator synchrony and decreasing respiratory work. After optimization of ventilator settings, external PEEP can be titrated to about 70% of static PEEPi with careful monitoring of plateau pressure during volume-cycled ventilation and tidal volume during pressure-cycled ventilation.

Key Points.

  • Dynamic hyperinflation and intrinsic PEEP (PEEPi) are commonly present in patients with COPD receiving mechanical ventilation.

  • PEEPi increases work of breathing and contributes to ineffective triggering of the ventilator.

  • The benefits of external PEEP in patients with COPD is dependent on the presence of airflow limitation and patient-triggered ventilation.

  • External PEEP can be titrated to about 70% of static PEEPi with careful monitoring of plateau pressure during volume-cycled ventilation and tidal volume during pressure-cycled ventilation.

Acknowledgment

Financial support and sponsorship:

This work was supported by a grant from National Institute of Nursing Research (RO1- NR016055)

Funding Source:

National Institute of Nursing Research (RO1- NR-016055)

Footnotes

Conflicts of interest: AJ has no conflict of interest.

References

  • 1.Esteban A, Anzueto A, Alia I, Gordo F, Apezteguia C, Palizas F, et al. How is mechanical ventilation employed in the intensive care unit? An international utilization review. Am J Respir Crit Care Med. 2000;161(5):1450–8. [DOI] [PubMed] [Google Scholar]
  • 2.Penuelas O, Muriel A, Abraira V, Frutos-Vivar F, Mancebo J, Raymondos K, et al. Inter-country variability over time in the mortality of mechanically ventilated patients. Intensive Care Med. 2020;46(3):444–53. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Gattinoni L, Marini JJ, Collino F, Maiolo G, Rapetti F, Tonetti T, et al. The future of mechanical ventilation: lessons from the present and the past. Crit Care. 2017;21(1):183. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Millington SJ, Cardinal P, Brochard L. Setting and Titrating Positive End-Expiratory Pressure. Chest. 2022;161(6):1566–75. [DOI] [PubMed] [Google Scholar]
  • 5.Fan E, Del Sorbo L, Goligher EC, Hodgson CL, Munshi L, Walkey AJ, et al. An Official American Thoracic Society/European Society of Intensive Care Medicine/Society of Critical Care Medicine Clinical Practice Guideline: Mechanical Ventilation in Adult Patients with Acute Respiratory Distress Syndrome. Am J Respir Crit Care Med. 2017;195(9):1253–63. [DOI] [PubMed] [Google Scholar]
  • 6.Officer TM, Pellegrino R, Brusasco V, Rodarte JR. Measurement of pulmonary resistance and dynamic compliance with airway obstruction. J Appl Physiol (1985). 1998;85(5):1982–8. [DOI] [PubMed] [Google Scholar]
  • 7.Jubran A, Tobin MJ. Pathophysiologic basis of acute respiratory distress in patients who fail a trial of weaning from mechanical ventilation. Am J Respir Crit Care Med. 1997;155(3):906–15. [DOI] [PubMed] [Google Scholar]
  • 8.Paredi P, Goldman M, Alamen A, Ausin P, Usmani OS, Pride NB, Barnes PJ. Comparison of inspiratory and expiratory resistance and reactance in patients with asthma and chronic obstructive pulmonary disease. Thorax. 2010;65(3):263–7. [DOI] [PubMed] [Google Scholar]
  • 9.Smith TC, Marini JJ. Impact of PEEP on lung mechanics and work of breathing in severe airflow obstruction. J Appl Physiol (1985). 1988;65(4):1488–99. [DOI] [PubMed] [Google Scholar]
  • 10.Tobin MJ, Laghi F, Jubran A. Ventilatory failure, ventilator support, and ventilator weaning. Compr Physiol. 2012;2(4):2871–921. [DOI] [PubMed] [Google Scholar]
  • 11.Eltayara L, Becklake MR, Volta CA, Milic-Emili J. Relationship between chronic dyspnea and expiratory flow limitation in patients with chronic obstructive pulmonary disease. Am J Respir Crit Care Med. 1996;154(6 Pt 1):1726–34. [DOI] [PubMed] [Google Scholar]
  • 12.Bernasconi M, Ploysongsang Y, Gottfried SB, Milic-Emili J, Rossi A. Respiratory compliance and resistance in mechanically ventilated patients with acute respiratory failure. Intensive Care Med. 1988;14(5):547–53. [DOI] [PubMed] [Google Scholar]
  • 13.Younes M Mechanisms of respiratory load compensation. In: Demsey JA, Pack AL, editors. Regulation of Breathing. New York: Marcel Dekker, Inc; 1995b. p. 867–922. [Google Scholar]
  • 14.Broseghini C, Brandolese R, Poggi R, Polese G, Manzin E, Milic-Emili J, Rossi A. Respiratory mechanics during the first day of mechanical ventilation in patients with pulmonary edema and chronic airway obstruction. Am Rev Respir Dis. 1988;138(2):355–61. [DOI] [PubMed] [Google Scholar]
  • 15.Pepe PE, Marini JJ. Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction: the auto-PEEP effect. Am Rev Respir Dis. 1982;126(1):166–70. [DOI] [PubMed] [Google Scholar]
  • 16.Derenne JP, Fleury B, Pariente R. Acute respiratory failure of chronic obstructive pulmonary disease. Am Rev Respir Dis. 1988;138(4):1006–33. [DOI] [PubMed] [Google Scholar]
  • 17.Gottfried SB, Reissman H, Ranieri VM. A simple method for the measurement of intrinsic positive end-expiratory pressure during controlled and assisted modes of mechanical ventilation. Crit Care Med. 1992;20(5):621–9. [DOI] [PubMed] [Google Scholar]
  • 18.Jubran A, Tobin MJ. Passive mechanics of lung and chest wall in patients who failed or succeeded in trials of weaning. Am J Respir Crit Care Med. 1997;155(3):916–21. [DOI] [PubMed] [Google Scholar]
  • 19.Rossi A, Gottfried SB, Zocchi L, Higgs BD, Lennox S, Calverley PM, et al. Measurement of static compliance of the total respiratory system in patients with acute respiratory failure during mechanical ventilation. The effect of intrinsic positive end-expiratory pressure. Am Rev Respir Dis. 1985;131(5):672–7. [DOI] [PubMed] [Google Scholar]
  • 20.Jubran A, Van de Graaff WB, Tobin MJ. Variability of patient-ventilator interaction with pressure support ventilation in patients with chronic obstructive pulmonary disease. Am J Respir Crit Care Med. 1995;152(1):129–36. [DOI] [PubMed] [Google Scholar]
  • 21.Jubran A, Laghi F, Mazur M, Parthasarathy S, Garrity ER Jr., Fahey PJ, Tobin MJ. Partitioning of lung and chest-wall mechanics before and after lung-volume-reduction surgery. Am J Respir Crit Care Med. 1998;158(1):306–10. [DOI] [PubMed] [Google Scholar]
  • 22.Maltais F, Reissmann H, Navalesi P, Hernandez P, Gursahaney A, Ranieri VM, et al. Comparison of static and dynamic measurements of intrinsic PEEP in mechanically ventilated patients. Am J Respir Crit Care Med. 1994;150(5 Pt 1):1318–24. [DOI] [PubMed] [Google Scholar]
  • 23.Zakynthinos SG, Vassilakopoulos T, Zakynthinos E, Roussos C. Accurate measurement of intrinsic positive end-expiratory pressure: how to detect and correct for expiratory muscle activity. Eur Respir J. 1997;10(3):522–9. [PubMed] [Google Scholar]
  • 24.Jubran A, Tobin MJ. Monitoring during mechanical ventilation. In: Tobin MJ, editor. Principles and practice of mechanical ventilation. New York: McGraw-Hill, Inc.; 2013. p. 261–87. [Google Scholar]
  • 25.Haluszka J, Chartrand DA, Grassino AE, Milic-Emili J. Intrinsic PEEP and arterial PCO2 in stable patients with chronic obstructive pulmonary disease. Am Rev Respir Dis. 1990;141(5 Pt 1):1194–7. [DOI] [PubMed] [Google Scholar]
  • 26.Fleury B, Murciano D, Talamo C, Aubier M, Pariente R, Milic-Emili J. Work of breathing in patients with chronic obstructive pulmonary disease in acute respiratory failure. Am Rev Respir Dis. 1985;131(6):822–7. [DOI] [PubMed] [Google Scholar]
  • 27.Parthasarathy S, Jubran A, Laghi F, Tobin MJ. Sternomastoid, rib cage, and expiratory muscle activity during weaning failure. J Appl Physiol. 2007;103(1):140–7. [DOI] [PubMed] [Google Scholar]
  • 28.Parthasarathy S, Jubran A, Tobin MJ. Cycling of inspiratory and expiratory muscle groups with the ventilator in airflow limitation. AmJRespirCrit Care Med. 1998;158(5 Pt 1):1471–8. [DOI] [PubMed] [Google Scholar]
  • 29.Ninane V, Yernault JC, de Troyer A. Intrinsic PEEP in patients with chronic obstructive pulmonary disease. Role of expiratory muscles. Am Rev Respir Dis. 1993;148(4 Pt 1):1037–42. [DOI] [PubMed] [Google Scholar]
  • 30.Appendini L, Purro A, Patessio A, Zanaboni S, Carone M, Spada E, et al. Partitioning of inspiratory muscle workload and pressure assistance in ventilator-dependent COPD patients. Am J Respir Crit Care Med. 1996;154(5):1301–9. [DOI] [PubMed] [Google Scholar]
  • 31.Coussa ML, Guerin C, Eissa NT, Corbeil C, Chasse M, Braidy J, et al. Partitioning of work of breathing in mechanically ventilated COPD patients. J Appl Physiol (1985). 1993;75(4):1711–9. [DOI] [PubMed] [Google Scholar]
  • 32.Tobin MJ, Jubran A, Laghi F. Fighting the ventilator. In: Tobin MJ, editor. Principles and practice of mechanical ventilation. New York: McGraw-Hill, Inc.; 2013. [Google Scholar]
  • 33.Leung P, Jubran A, Tobin MJ. Comparison of assisted ventilator modes on triggering, patient effort, and dyspnea. Am J Respir Crit Care Med. 1997;155(6):1940–8. [DOI] [PubMed] [Google Scholar]
  • 34.Tobin MJ, Jubran A, Laghi F. Patient-ventilator interaction. Am J RespirCrit Care Med. 2001;163(5):1059–63. [DOI] [PubMed] [Google Scholar]
  • 35.Lessard MR, Lofaso F, Brochard L. Expiratory muscle activity increases intrinsic positive end-expiratory pressure independently of dynamic hyperinflation in mechanically ventilated patients. Am J Respir Crit Care Med. 1995;151(2 Pt 1):562–9. [DOI] [PubMed] [Google Scholar]
  • 36.Yan S, Kayser B, Tobiasz M, Sliwinski P. Comparison of static and dynamic intrinsic positive end-expiratory pressure using the Campbell diagram. Am J Respir Crit Care Med. 1996;154(4 Pt 1):938–44. [DOI] [PubMed] [Google Scholar]
  • **37. Marini JJ. Dynamic hyperinflation and auto-positive end-expiratory pressure: lessons learned over 30 years. Am J Respir Crit Care Med. 2011;184(7):756–62. (This paper is a comprehensive review of physiology and management of auto-PEEP)
  • 38.Jubran A, Mathru M, Dries D, Tobin MJ. Continuous recordings of mixed venous oxygen saturation during weaning from mechanical ventilation and the ramifications thereof. Am J Respir Crit Care Med. 1998;158(6):1763–9. [DOI] [PubMed] [Google Scholar]
  • 39.Rogers PL, Schlichtig R, Miro A, Pinsky M. Auto-PEEP during CPR. An “occult” cause of electromechanical dissociation? Chest. 1991;99(2):492–3. [DOI] [PubMed] [Google Scholar]
  • 40.Lapinsky SE, Leung RS. Auto-PEEP and electromechanical dissociation. N Engl J Med. 1996;335(9):674. [DOI] [PubMed] [Google Scholar]
  • 41.Luks AM, Pierson DI. Barotrauma and bronchopleural fistula. In: Tobin MJ, editor. Principles and practice of mechanical ventilation. New York: McGraw-Hill, Inc.; 2023. p. 1041–64. [Google Scholar]
  • 42.Tuxen DV. Permissive hypercapnic ventilation. Am J Respir Crit Care Med. 1994;150(3):870–4. [DOI] [PubMed] [Google Scholar]
  • 43.Laghi F, Karamchandani K, Tobin MJ. Influence of ventilator settings in determining respiratory frequency during mechanical ventilation. Am J RespirCrit Care Med. 1999;160(5 Pt 1):1766–70. [DOI] [PubMed] [Google Scholar]
  • 44.Laghi F, Segal J, Choe WK, Tobin MJ. Effect of imposed inflation time on respiratory frequency and hyperinflation in patients with chronic obstructive pulmonary disease. Am J Respir Crit Care Med. 2001;163(6):1365–70. [DOI] [PubMed] [Google Scholar]
  • 45.Appendini L, Patessio A, Zanaboni S, Carone M, Gukov B, Donner CF, Rossi A. Physiologic effects of positive end-expiratory pressure and mask pressure support during exacerbations of chronic obstructive pulmonary disease. Am J Respir Crit Care Med. 1994;149(5):1069–76. [DOI] [PubMed] [Google Scholar]
  • 46.Tobin MJ, Lodato RF. PEEP, auto-PEEP, and waterfalls. Chest. 1989;96(3):449–51. [DOI] [PubMed] [Google Scholar]
  • 47.Marini JJ. Should PEEP be used in airflow obstruction? Am Rev Respir Dis. 1989;140(1):1–3. [DOI] [PubMed] [Google Scholar]
  • 48.Tuxen DV. Detrimental effects of positive end-expiratory pressure during controlled mechanical ventilation of patients with severe airflow obstruction. Am Rev Respir Dis. 1989;140(1):5–9. [DOI] [PubMed] [Google Scholar]
  • 49.Petrof BJ, Legare M, Goldberg P, Milic-Emili J, Gottfried SB. Continuous positive airway pressure reduces work of breathing and dyspnea during weaning from mechanical ventilation in severe chronic obstructive pulmonary disease. Am Rev Respir Dis. 1990;141(2):281–9. [DOI] [PubMed] [Google Scholar]
  • 50.Ranieri VM, Giuliani R, Cinnella G, Pesce C, Brienza N, Ippolito EL, et al. Physiologic effects of positive end-expiratory pressure in patients with chronic obstructive pulmonary disease during acute ventilatory failure and controlled mechanical ventilation. Am Rev Respir Dis. 1993;147(1):5–13. [DOI] [PubMed] [Google Scholar]
  • 51.Nava S, Bruschi C, Rubini F, Palo A, Iotti G, Braschi A. Respiratory response and inspiratory effort during pressure support ventilation in COPD patients. Intensive Care Med. 1995;21(11):871–9. [DOI] [PubMed] [Google Scholar]
  • **52. Demoule A, Brochard L, Dres M, Heunks L, Jubran A, Laghi F, et al. How to ventilate obstructive and asthmatic patients. Intensive Care Med. 2020;46(12):2436–49. (This paper provides a state-of-the-art review on ventilator strategies in patients with COPD, with special emphasis on the role of PEEP in COPD.)
  • 53.Laghi F Mechanical ventilation in chronic obstructive pulmonary disease. In: Tobin MJ, editor. Principles and practice of mechanical ventilation. New York: McGraw-Hill, Inc.; 2013. p. 741–60. [Google Scholar]
  • 54.Caramez MP, Borges JB, Tucci MR, Okamoto VN, Carvalho CR, Kacmarek RM, et al. Paradoxical responses to positive end-expiratory pressure in patients with airway obstruction during controlled ventilation. Crit Care Med. 2005;33(7):1519–28. [DOI] [PMC free article] [PubMed] [Google Scholar]

RESOURCES