Skip to main content
. 2024 May 1;16(5):e59493. doi: 10.7759/cureus.59493

Table 5. Comparison of discard rates in this study with those of other studies and reasons for discarding blood units.

Literature Total discard (%) Expiry (%) TTI (%) Bag breakage (%)  
Kanani et al. [2] 7.0 43.4 11.3 13.7
Kumar et al. [4] 8.4 57.8 33.8 3.0
Patil et al. [5] 20.6 53 33.0 3.4
Anitha et al. [6] 4.6 21.9 63.6 10.8
Luhar et al. [7] 2.96 21.06 35.06 13.84
Kulkarni et al. [8] 68.33 14.5 54.75 27.0
Suresh et al. [9] 7.0 7.5 37.9 1.6
Bobde et al. [10] 8.2 51.4 19.5 34.5
Deb et al. [11] 14.6 82.8 17.2 -
Sharma et al. [12] 8.69 54.5 20 25.6
This study (2023, South India) 18 97 2.9 0.01