Skip to main content
. 2024 May 18;47:100797. doi: 10.1016/j.ctro.2024.100797

Table 2.

Consensus protocol for five-fraction MR-guided SBRT for pancreas. Target objectives are subject to concession if OAR constraints cannot be met. There is no specific maximum dose limit to the GTV.

Parameter Value
Prescription dose (#fractions x dose) 5x10 Gy
GTV V100% >95 %
PTV V95% >95 %
Duodenum, large bowel, stomach D0.cc < 35 Gy
Small bowel D0.cc < 40 Gy
Biliary duct D0.cc < 50 Gy
Large vessels (aorta, inferior vena cava) D0.cc < 53 Gy
Superior mesenteric artery D0.cc < 53 Gy
Celiac trunk D0.cc < 53 Gy
Kidneys Dmean < 10 Gy; D67% < 16.8 Gy
Spinal cord D0.cc < 28 Gy
GTV-PTV margin 2 mm with active motion management
Number of beams 9–14
Number of segments As low as reasonably possible (lower limit = 45)
Passive motion management Abdominal compression
Arms position Arms down