Table 4.
No. | Location Name | HI | Risk Rating |
High-Risk Parameters | Control Measures | |
---|---|---|---|---|---|---|
1 | Drill Pattern | 0.10 | 6 | H | Noise, PM10 | Every worker at these places must wear appropriate PPE and an HCN alarm. Gas detectors in areas with high HCN |
2 | Underground Area 1(740 Access) | 3.75 | 6 | H | Noise, PM10 CO, HCN |
|
3 | Underground Area 2 (Tagboard 770) | 3.04 | 6 | H | ||
4 | Underground Area 3 | 2.30 | 6 | H | ||
5 | Power Generators House | 0.60 | 6 | H | Noise | |
6 | Power station stacks Area | 0.36 | 6 | H | Noise | |
7 | Inside Laboratory (Sample Preparation) | 0.14 | 6 | H | PM10 | |
8 | Air Compressor Area | 0.12 | 6 | H | Noise | |
9 | Mills Area | 0.42 | 6 | H | Noise | |
10 | Carbon Leaching Tanks Area (1) | 2.86 | 24 | H | HCN | |
11 | Carbon Leaching Tank Area (2) | 2.25 | 24 | H | HCN | |
12 | At Lime Area | 0.09 | 23 | M | PM10 |