Skip to main content
. 2024 May 22;10(11):e31086. doi: 10.1016/j.heliyon.2024.e31086

Table 4.

High/medium risk site locations at SGM site.

No. Location Name HI Risk
Rating
High-Risk Parameters Control Measures
1 Drill Pattern 0.10 6 H Noise, PM10 Every worker at these places must wear appropriate PPE and an HCN alarm. Gas detectors in areas with high HCN
2 Underground Area 1(740 Access) 3.75 6 H Noise, PM10
CO, HCN
3 Underground Area 2 (Tagboard 770) 3.04 6 H
4 Underground Area 3 2.30 6 H
5 Power Generators House 0.60 6 H Noise
6 Power station stacks Area 0.36 6 H Noise
7 Inside Laboratory (Sample Preparation) 0.14 6 H PM10
8 Air Compressor Area 0.12 6 H Noise
9 Mills Area 0.42 6 H Noise
10 Carbon Leaching Tanks Area (1) 2.86 24 H HCN
11 Carbon Leaching Tank Area (2) 2.25 24 H HCN
12 At Lime Area 0.09 23 M PM10