Skip to main content
. 2024 Jan 22;24:137–144. doi: 10.1016/j.xjtc.2024.01.015

Table 3.

Operative and postoperative data

Operative and postoperative data Hybrid method (n = 234) Traditional method (n = 266) P value
Size of device used, range, mm 4-14
Success rate, n (%) 233 (93.2) 250 (100) .001
Hospital mortality, n (%) 1 (0.4) 4 (1.5) <.000
Conversion cases, n (%) 16 (6,4)
Intraoperative blood loss, mL 27 31 .463
Operation time, min (min; max) 84 (31; 160) 168 (70; 300) <.000
CPB times, min (min; max) 72 (28; 150)
Crossclamping time, min (min; max) 36 (10; 70)
Left ventricular ejection fraction (%) (before surgery) (min; max) 65.5 (59; 78) 65 (40; 78) .465
Left ventricular ejection fraction (%) (after surgery) (min; max) 60.7 (55; 68) 59.6 (45; 67) <.000
Residual shunts, n (%) 16 (6.84) 19 (7.14) .612
Before operation stay, d 3.12 6.24 <.000
After the operation stay, d 6.76 11.13 <.000
Intensive care unit stay, d 1.03 2.5 <.000
Total hospital stay with first step rehabilitation, d 9.88 17.35 <.000

CPB, Cardiopulmonary bypass.