Skip to main content
. 2024 May 22;9(22):23634–23648. doi: 10.1021/acsomega.4c01219

Table 6. Stability at LQC and HQC Levels of DEM and DEX in Rat Plasma (n = 6).

stability analyte nominal conc. (ng/mL) calculated conc. (ng/mL) precision (% CV) % difference
benchtop stability (19 h and 28 min) DEM 0.58 0.59 ± 0.05 8.47 5.29
302.52 300.16 ± 11.76 3.92 –0.36
DEX 0.30 0.29 ± 0.02 6.9 0.00
156.76 153.91 ± 5.91 3.84 –0.70
wet extract stability (42 h and 12 min) DEM 0.58 0.61 ± 0.05 8.20 8.86
302.52 298.73 ± 10.53 3.52 –0.83
DEX 0.30 0.31 ± 0.02 6.45 6.90
156.76 153.92 ± 5.87 3.81 –0.69
processed sample stability (28 h and 21 min) DEM 0.58 0.56 ± 0.03 5.36 –0.06
302.52 308.31 ± 8.23 2.67 2.35
DEX 0.30 0.030 ± 0.01 3.33 3.45
156.76 151.91 ± 3.03 1.99 –1.99
freeze thaw stability (five cycles) DEM 0.58 0.57 ± 0.03 5.26 1.72
302.52 293.62 ± 16.24 5.53 –2.53
DEX 0.30 0.30 ± 0.02 6.67 3.45
156.76 156.02 ± 1.22 0.78 0.66
autosampler stability (64 h and 3 min) DEM 0.58 0.58 ± 0.03 5.17 3.51
302.52 308.23 ± 7.69 2.49 2.32
DEX 0.30 0.28 ± 0.02 7.14 –3.45
156.76 149.71 ± 5.67 3.79 –3.41
long-term stability (49 days) DEM 0.58 0.58 ± 0.03 5.17 3.51
302.52 299.62 ± 9.41 3.14 –0.54
DEX 0.30 0.30 ± 0.02 6.67 3.45
156.76 155.49 ± 7.51 4.83 0.32