Skip to main content
. 2024 Jun 5;12:20503121241258071. doi: 10.1177/20503121241258071

Table 2.

Concentration of E. coli O157: H7 in drinking water and log10 reduction values.

Sample source E. coli O157: H7 (MPN/100 ml)
Mean SE SD Left Right Max Min
Water wells (C0) 4.355 3.297 17.364 1.058 7.652 112 0
Desalination plants (CDP) 0.541 0.574 3.023 −0.033 1.115 20.9 0
Tanker trucks (CTR) 0.93 0.685 4.876 0.245 1.615 39.5 0
Desalinated water at households (CHD) 0.598 0.412 4.107 0.186 1.01 39.2 0
Municipal water at households (CHT) 1.725 0.797 7.944 0.928 2.522 72.9 0
Private wells (CPW) 5.696 4.163 17.067 1.533 9.859 112 0
Private well water at households (CHP) 9.097 5.246 21.506 3.851 14.343 101.2 0
DWSS reference points log10 reduction value (Log)
Mean SE SD Left Right Max Min
LRV1 2.715 0.221 11.25 2.494 2.936 82.202 −46.233
LRV2 7.09 0.29 14.817 6.8 7.38 111.907 −52.24
LRV3 −1.465* 0.348 17.75 −1.813 −1.117 92.552 −107.684
LRV4 8.5 0.473 24.137 8.027 8.973 208.069 −95.721
LRV5 −1.465* 0.088 4.513 −1.553 −1.377 22.915 −36.819