Skip to main content
. 2024 Jun 6;10:65. doi: 10.1038/s41526-024-00403-6

Table 1.

Measured quantities and uncertainties

Symbol Quantity Measurement method Uncertainty
T Tank wall temperature T-type thermocouple 1 K or 1.5% below 273 K
Pc Tank pressure Kulite CTL-190M140BARA 7 kPa
δ Tank wall thickness Caliper 0.03 mm
LN2 mass flow rate Coriolis flow meter 0.3%
M Mass of the fluid components (tube, tee, nozzle) scale 0.1 g