Skip to main content
. 2024 Jun 6;10:65. doi: 10.1038/s41526-024-00403-6

Table 6.

CHV chilldown efficiency as a function of total number of parabolas involved

Number of Parabolas involved Consumed Mass, kg Efficiency, %
1 0.5459 48.83
1 + 2 1.0827 38.76
1 + 2 + 3 1.6510 34.08
1 + 2 + 3 + 4 2.2376 26.40
1 + 2 + 3 + 4 + 5 2.8314 20.40