Centrifugal pump input parameters and assumptions.

No. Parameter Symbol Value Units Note
1 Head H 5 (m) (BEP) of the baseline model
2 Volumetric flow rate Q 3.8 (m3/s)
3 Rotational speed n 1500 (rpm)
4 Impeller type Type 2 (–) 1. Closed (or) 2. Semi-open
5 Inlet flow angle α1 90 ()
6 Meridional velocity ratio c2m/c1m 1 (–)
7 Blade count z 6 (–)
8 Impeller entry count fq 1 (–) 1. Single (or) 2. Double
9 Hub to shaft diameter ratio dw/dn 1.5 (–)
10 Leading edge profile LEp 2 (–) 1. Semi-circle, 2. Elliptic (or) 3. Wedge
11 Trailing edge profile TEp 1 (–) 1. Tapered (or) 2. Full thickness