Skip to main content
. 2024 May 22;14(11):904. doi: 10.3390/nano14110904

Table 6.

Results of phosphogypsum heat treatment with different reducing agent contents at different temperatures.

Reducing Agent Mass, g Reducing Agent Mole Fraction, % Relative Luminous Flux (Rel. Units)
at Treatment Temperature
1073 К 1173 К 1273 К
1.10 6.40 0.24 0.10 0.10
2.10 12.21 0.39 0.12 0.10
4.30 25.00 0.86 0.35 0.15
6.40 37.21 0.93 0.75 0.15
8.50 49.42 0.91 0.90 0.15
10.70 62.21 0.90 0.88 0.10
12.80 74.42 0.84 0.80 0.26
17.10 99.42 0.63 0.60 0.21