Skip to main content
. 2024 Jun 3;9(24):25766–25778. doi: 10.1021/acsomega.3c10078

Table 2. Membrane Filtration Performance at a 2 bar Pressure.

membrane pure water flux (Jf1) (L m–2 h–1) BSA flux (Jb) (L m–2 h–1) water flux after the wash (Jf2) (L m–2 h–1)
VPM-0 93.40 ± 1.21 53.01 ± 0.20 63.11 ± 1.30
VPM-1 214.57 ± 1.86 138.84 ± 3.10 146.41 ± 1.30
VPM-2 247.39 ± 3.80 164.08 ± 2.96 184.28 ± 1.21
VPM-3 191.85 ± 1.06 121.17 ± 1.30 131.26 ± 2.21