Table 3.
Performance characteristics at each cutoff of SARC-F (a), SARC-CalF (b), and SARC-F + EBM (c) with sensitivity, specificity, false positive rate, and Youden index.
| Test | Cutoff ≥ | Sensitivity | Specificity | False positive rate | Youden index |
|---|---|---|---|---|---|
| a. SARC-F ≥ | |||||
| 1 | 81.0 | 29.7 | 24.6 | 0.107 | |
| 2 | 52.4 | 37.8 | 19.3 | − 0.098 | |
| 3 | 42.9 | 59.5 | 23.1 | 0.024 | |
| 4 | 28.6 | 75.7 | 25.0 | 0.043 | |
| 5 | 4.8 | 87.8 | 10.0 | − 0.074 | |
| b. SARC-CalF ≥ | |||||
| 8 | 90.5 | 67.6 | 44.2 | 0.570 | |
| 9 | 90.5 | 67.6 | 44.2 | 0.570 | |
| 10 | 90.5 | 68.9 | 45.2 | 0.584 | |
| 11 | 76.2 | 78.4 | 50.0 | 0.536 | |
| 12 | 52.4 | 82.4 | 45.8 | 0.338 | |
| c. SARCF + EBM ≥ | |||||
| 8 | 77.3 | 84.6 | 58.6 | 0.609 | |
| 9 | 77.3 | 84.6 | 58.6 | 0.609 | |
| 10 | 77.3 | 87.2 | 63.0 | 0.635 | |
| 11 | 59.1 | 93.6 | 72.2 | 0.517 | |
| 12 | 40.9 | 96.2 | 75.0 | 0.361 | |
Youden index = (Sensitivity + Specificity − 1).