Skip to main content
. 2024 Jun 5;11(6):572. doi: 10.3390/bioengineering11060572

Table 1.

Comparison of the strength and maximum displacement of the femur bone before and after reinforcement.

Test Specimen Maximum Force
(kN)
Displacement at Maximum Force (mm)
Pressure test of femur bone without strengthening Specimen 1.1 3.42 6.00
Specimen 1.2 3.64 6.49
Specimen 1.3 5.19 6.47
AVERAGE 4.08 ± 0.96 6.32 ± 0.28
Pressure test of femur bone with strengthening Specimen 2.1 4.45 7.05
Specimen 2.2 3.69 6.65
Specimen 2.3 5.57 8.1
AVERAGE 4.57 ± 0.94 7.27 ± 0.75
Three-point bending of femur bone without strengthening Specimen 3.1 4.3 6.65
Specimen 3.2 3.89 8.1
Specimen 3.3 4.05 8.87
AVERAGE 4.08 ± 0.21 7.87 ± 1.12
Three-point bending of femur bone with strengthening Specimen 4.1 4.59 7.33
Specimen 4.2 4.51 10.59
Specimen 4.3 5.26 8.38
AVERAGE 4.79 ± 0.41 8.76 ± 1.66