Skip to main content
. 2024 Jun 8;14(12):1219. doi: 10.3390/diagnostics14121219

Table 3.

Comparison of selected POCT parameters in arterial and venous samples, presented separately for non-HD and HD patients.

non-HD A V p
p50 (mmHg) 26.89 ± 2.02 26.81 ± 1.83 0.66
pH 7.33 ± 0.06 7.27 ± 0.07 <0.01
pCO2 (mmHg) 34.44 ± 4.98 37.06 ± 5.04 <0.01
HCO3 (mmol/L) 18.49 ± 3.99 17.62 ± 4.02 <0.01
Anion gap (mmol/L) 9.78 ± 2.33 11.17 ± 2.49 <0.01
ABE (mmol/L) −6.62 ± 4.34 −8.47 ± 4.67 <0.01
SBE (mmol/L) −7.37 ± 4.78 −9.14 ± 5.06 <0.01
HD A V p
p50 (mmHg) 26.68 ± 1.99 27.34 ± 1.84 <0.01
pH 7.38 ± 0.05 7.32 ± 0.06 <0.01
pCO2 (mmHg) 37.06 ± 4.66 41.09 ± 4.65 <0.01
HCO3 (mmol/L) 22.70 ± 2.95 20.68 ± 2.93 <0.01
Anion gap (mmol/L) 10.49 ± 2.34 12.39 ± 2.37 <0.01
ABE (mmol/L) −2.07 ± 3.64 −4.41 ± 3.79 <0.01
SBE (mmol/L) −2.39 ± 4.00 −4.61 ± 4.07 <0.01

Student’s t-test for dependent variables, p-value < 0.05 statistically significant. Abbreviation: A, arterial sample; V, vein sample; HD, hemodialysis; pCO2, carbon dioxide partial pressure; HCO3, bicarbonate; SBE, standard base excess; ABE, actual base excess.